A novel digital image colorimetric analysis system with adaptive sensitivity and measuring range

Abstract In this study, we aimed at developing an innovative digital image colorimetry (DIC) system, designated CAS-t, which integrates advanced hardware and software components. The CAS-t platform includes a fully enclosed illumination chamber with uniform LED lighting diffused by a polyethylene material, a camera positioned 25 cm above a 96-well microplate with an additional lens to reduce lateral distortion, and an adjustable exposure time to optimize performance. An image-processing algorithm within a Python workflow detects circular wells in a microplate, applies median filtering, and extracts RGB intensities analyzed via principal component analysis (PCA). The experimental results obtained from phenol red (PR) and indigo carmine (IC) indicators demonstrated that exposure time significantly influences the sensitivity and measurable concentration ranges, thereby allowing tunable detection parameters. For IC, increasing exposure time from 1 to 5 ms increased the slope magnitude from −0.014 to −0.027 µM⁻¹, whereas PR showed the opposite trend. Compared with the reflected-light systems and smartphone cameras, CAS-t achieved approximately two-fold higher sensitivity (−27.0 versus −14.0 µM⁻¹) and markedly improved precision (RSD: 5.75% versus 25.39%). As a proof concept, Fe(II) content in a pharmaceutical sample was quantified by performing CAS-t system calibrated using standard solutions (0.1–5.0 mg L⁻¹) of Fe(II) versus PC1 as the most sensitive and linear color channel (R² = 0.999). Validation against the reference UV-Vis spectrometer showed strong statistical agreement at 95% confidence (p > 0.05), confirming the reliability of the 7 ms as optimal exposure time chosen based on sensitivity and linearity analyses. Consequently, this integrated hardware-software approach offers a standardized framework for DIC assays with broad adaptability across diverse chemical and biochemical applications.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2026-11-02
DOI
https://doi.org/10.1088/1361-6501/aebca5
Primary Topic
Color Science and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel digital image colorimetric analysis system with adaptive sensitivity and measuring range

Ali Gelir, Onur Özdemir, Orhan Destanoğlu, Mustafa Özcan et al.
3 links
Measurement Science and Technology
Color Science and Applications
article

A novel digital image colorimetric analysis system with adaptive sensitivity and measuring range

Ali Gelir, Onur Özdemir, Orhan Destanoğlu, Mustafa Özcan, Sedat Özdemir, Kenan Arslan
article en

Abstract

Abstract In this study, we aimed at developing an innovative digital image colorimetry (DIC) system, designated CAS-t, which integrates advanced hardware and software components. The CAS-t platform includes a fully enclosed illumination chamber with uniform LED lighting diffused by a polyethylene material, a camera positioned 25 cm above a 96-well microplate with an additional lens to reduce lateral distortion, and an adjustable exposure time to optimize performance. An image-processing algorithm within a Python workflow detects circular wells in a microplate, applies median filtering, and extracts RGB intensities analyzed via principal component analysis (PCA). The experimental results obtained from phenol red (PR) and indigo carmine (IC) indicators demonstrated that exposure time significantly influences the sensitivity and measurable concentration ranges, thereby allowing tunable detection parameters. For IC, increasing exposure time from 1 to 5 ms increased the slope magnitude from −0.014 to −0.027 µM⁻¹, whereas PR showed the opposite trend. Compared with the reflected-light systems and smartphone cameras, CAS-t achieved approximately two-fold higher sensitivity (−27.0 versus −14.0 µM⁻¹) and markedly improved precision (RSD: 5.75% versus 25.39%). As a proof concept, Fe(II) content in a pharmaceutical sample was quantified by performing CAS-t system calibrated using standard solutions (0.1–5.0 mg L⁻¹) of Fe(II) versus PC1 as the most sensitive and linear color channel (R² = 0.999). Validation against the reference UV-Vis spectrometer showed strong statistical agreement at 95% confidence (p > 0.05), confirming the reliability of the 7 ms as optimal exposure time chosen based on sensitivity and linearity analyses. Consequently, this integrated hardware-software approach offers a standardized framework for DIC assays with broad adaptability across diverse chemical and biochemical applications.

Measurement Science and Technology
Istanbul University-Cerrahpaşa (TR), Istanbul Technical University (TR)
Openalex Percentile: Top 23%
Color Science and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon