Physiological Adaptations to Controlled Work Rate Heat Acclimation Do Not Differ Between Highly Trained Male and Female Endurance Runners

The purpose of this study was to determine whether the trajectory and magnitude of physiological adaptation to controlled work rate heat acclimation (HEAT) differ between male and female highly trained endurance runners, while comparing adaptations with work rate matched temperate exercise training (TEMP). Eighteen highly trained endurance runners (8 males, 10 females) completed two seven-session interventions consisting of HEAT (40°C, 35% relative humidity [RH]) and TEMP (22°C, 35% RH) in a randomized, counterbalanced crossover design. Each session consisted of 60 min of running at 50% of velocity at maximal oxygen uptake. Physiological adaptation was quantified as the change (Δ) relative to session 1 for core temperature (T c ), skin temperature, heart rate (HR), whole-body sweat rate (WBSR), and plasma volume (PV). No intervention × sex × session interactions were observed for T c , HR, or WBSR (p > 0.05), indicating that the trajectory of adaptation did not differ between sexes or interventions. Likewise, no sex differences in the overall magnitude of adaptation were observed for any HEAT outcome. Significant main effects of intervention demonstrated greater reductions in mean and peak T c ; baseline, mean, and peak HR; as well as greater increases in WBSR during HEAT compared with TEMP (p < 0.05). PV did not change following either intervention. Male and female highly trained endurance runners exhibited comparable thermoregulatory and cardiovascular adaptation to controlled work rate heat acclimation. Although work rate matched temperate exercise induced partial physiological adaptation, environmental heat stress enhanced the overall adaptation magnitude without altering the adaptation trajectory between sexes.

Authors

Institutions

Publication Details

Journal
Journal of Applied Physiology
Published
2026-11-02
DOI
https://doi.org/10.1152/japplphysiol.90119.2026
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Physiological Adaptations to Controlled Work Rate Heat Acclimation Do Not Differ Between Highly Trained Male and Female Endurance Runners

Heather L. Vellers, Danielle Evé Levitt, Courteney L. Benjamin, Marcos S. Keefe et al.
4 links
Journal of Applied Physiology
Thermoregulation and physiological responses
article

Physiological Adaptations to Controlled Work Rate Heat Acclimation Do Not Differ Between Highly Trained Male and Female Endurance Runners

Heather L. Vellers, Danielle Evé Levitt, Courteney L. Benjamin, Marcos S. Keefe, Yasuki Sekiguchi, Ryan A. Dunn
article en

Abstract

The purpose of this study was to determine whether the trajectory and magnitude of physiological adaptation to controlled work rate heat acclimation (HEAT) differ between male and female highly trained endurance runners, while comparing adaptations with work rate matched temperate exercise training (TEMP). Eighteen highly trained endurance runners (8 males, 10 females) completed two seven-session interventions consisting of HEAT (40°C, 35% relative humidity [RH]) and TEMP (22°C, 35% RH) in a randomized, counterbalanced crossover design. Each session consisted of 60 min of running at 50% of velocity at maximal oxygen uptake. Physiological adaptation was quantified as the change (Δ) relative to session 1 for core temperature (T c ), skin temperature, heart rate (HR), whole-body sweat rate (WBSR), and plasma volume (PV). No intervention × sex × session interactions were observed for T c , HR, or WBSR (p > 0.05), indicating that the trajectory of adaptation did not differ between sexes or interventions. Likewise, no sex differences in the overall magnitude of adaptation were observed for any HEAT outcome. Significant main effects of intervention demonstrated greater reductions in mean and peak T c ; baseline, mean, and peak HR; as well as greater increases in WBSR during HEAT compared with TEMP (p < 0.05). PV did not change following either intervention. Male and female highly trained endurance runners exhibited comparable thermoregulatory and cardiovascular adaptation to controlled work rate heat acclimation. Although work rate matched temperate exercise induced partial physiological adaptation, environmental heat stress enhanced the overall adaptation magnitude without altering the adaptation trajectory between sexes.

Journal of Applied Physiology
Texas Tech University (US), Hope College (US)
Good health and well-being
Openalex Percentile: Top 15%
Thermoregulation and physiological responses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon