Sorbent-based active sampling method for the simultaneous analysis of very volatile, volatile, and semi-volatile organic compounds
for 76% of analytes and were comparable to or lower than literature values. Humidity effects were most pronounced for highly polar compounds but were less influential than PLOT column length. A 3 m PLOT column enabled analysis of the entire analyte range in a single run, albeit with reduced chromatographic resolution. This limitation was largely mitigated by evaluating characteristic target ions. Extending the PLOT column to 6 m substantially improved resolution but decreased sensitivity for SVOCs. The optimum column configuration therefore depends on the analytical objective. The proposed method enables simultaneous characterisation of indoor air contaminants across a broad volatility range and may improve the efficiency and cost-effectiveness of emission testing and indoor air investigations.