Assessing EPC-derived gas consumption estimates using metered data: A case study in Turin

Buildings are major contributors to both energy consumption and carbon emissions, making them a key target for emission reduction. In the European Union, Energy Performance Certificates (EPCs) are widely used in urban building energy modelling; however, EPC-derived estimates may differ from actual consumption, while incomplete coverage limits their application. This study investigates the consistency between EPC-derived natural gas consumption estimates and metered data in Turin, Italy. The analysis covers 128,225 volumetric units, of which 22,551 (17.59%) are associated with at least one EPC. Results show overestimation by EPC-based estimates, with discrepancies exceeding 90% for the least efficient classes. For non-district-heating units, the median EPC estimate for Class G exceeds 230 kWh/m²/y, compared with a metered median of approximately 9 kWh/m²/y. To address these discrepancies, empirical Correction Factors (CFs) are derived for different energy performance classes and building characteristics. The results provide an empirical assessment of EPC-based natural gas consumption estimates at urban scale and demonstrate the potential of data-driven Correction Factors to improve their consistency with measured consumption.

Authors

Institutions

Publication Details

Journal
Energy Reports
Published
2026-11-02
DOI
https://doi.org/10.1016/j.egyr.2026.109810
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing EPC-derived gas consumption estimates using metered data: A case study in Turin

M. Ferrara, S. Anselmo, M.V. Airoma
Energy Reports
Building Energy and Comfort Optimization
article

Assessing EPC-derived gas consumption estimates using metered data: A case study in Turin

M. Ferrara, S. Anselmo, M.V. Airoma
article en

Abstract

Buildings are major contributors to both energy consumption and carbon emissions, making them a key target for emission reduction. In the European Union, Energy Performance Certificates (EPCs) are widely used in urban building energy modelling; however, EPC-derived estimates may differ from actual consumption, while incomplete coverage limits their application. This study investigates the consistency between EPC-derived natural gas consumption estimates and metered data in Turin, Italy. The analysis covers 128,225 volumetric units, of which 22,551 (17.59%) are associated with at least one EPC. Results show overestimation by EPC-based estimates, with discrepancies exceeding 90% for the least efficient classes. For non-district-heating units, the median EPC estimate for Class G exceeds 230 kWh/m²/y, compared with a metered median of approximately 9 kWh/m²/y. To address these discrepancies, empirical Correction Factors (CFs) are derived for different energy performance classes and building characteristics. The results provide an empirical assessment of EPC-based natural gas consumption estimates at urban scale and demonstrate the potential of data-driven Correction Factors to improve their consistency with measured consumption.

Energy ReportsVol. 16
Politecnico di Torino (IT)
Politecnico di Torino
Affordable and clean energy, Climate action
Openalex Percentile: Top 19%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon