Experimental study on water recovery from high‐humidity flue gas using condensation combined with acoustic agglomeration

Abstract High‐humidity flue gas downstream of wet flue‐gas desulfurization (WFGD) contains recoverable water, whereas indirect condensation alone may provide limited recovery under laboratory conditions. Although condensation–acoustic agglomeration arrangements have been reported for flue‐gas treatment, the water‐collection response of the present laboratory system and its dependence on cooling and acoustic variables required clarification. Here, a simulated high‐humidity flue gas was treated using a Flue Gas Condenser combined with an acoustic agglomeration chamber. The effects of cooling‐water flow rate, cooling‐water inlet temperature, water‐vapor volume fraction, acoustic frequency, sound pressure level (SPL), and nominal residence time were evaluated. Under the reported optimum cooling condition at 55°C and α = 17%, condensation alone achieved a water‐recovery efficiency of 38.51%. With the acoustic field operated at 1000 Hz, 130 dB, and a nominal residence time of 5 s, the reported recovery reached 46.93%, an increase of 8.42 percentage points (21.9% relative to condensation alone). The observed non‐monotonic responses to frequency, SPL, and residence time identify an operating window for the tested apparatus. These findings provide an experimental reference for optimizing operating conditions in condensation–acoustic agglomeration systems and support further evaluation for water recovery from representative high‐humidity WFGD gas.

Authors

Institutions

Publication Details

Journal
Environmental Progress & Sustainable Energy
Published
2026-11-02
DOI
https://doi.org/10.1002/ep.70779
Primary Topic
Industrial Gas Emission Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study on water recovery from high‐humidity flue gas using condensation combined with acoustic agglomeration

胡宇峰, Hengyuan Liu, Zhaoping Zhong, Yueyang Xu et al.
Environmental Progress & Sustainable Energy
Industrial Gas Emission Control
article

Experimental study on water recovery from high‐humidity flue gas using condensation combined with acoustic agglomeration

胡宇峰, Hengyuan Liu, Zhaoping Zhong, Yueyang Xu, Yuhan Xu, Wenfeng Liu
article en

Abstract

Abstract High‐humidity flue gas downstream of wet flue‐gas desulfurization (WFGD) contains recoverable water, whereas indirect condensation alone may provide limited recovery under laboratory conditions. Although condensation–acoustic agglomeration arrangements have been reported for flue‐gas treatment, the water‐collection response of the present laboratory system and its dependence on cooling and acoustic variables required clarification. Here, a simulated high‐humidity flue gas was treated using a Flue Gas Condenser combined with an acoustic agglomeration chamber. The effects of cooling‐water flow rate, cooling‐water inlet temperature, water‐vapor volume fraction, acoustic frequency, sound pressure level (SPL), and nominal residence time were evaluated. Under the reported optimum cooling condition at 55°C and α = 17%, condensation alone achieved a water‐recovery efficiency of 38.51%. With the acoustic field operated at 1000 Hz, 130 dB, and a nominal residence time of 5 s, the reported recovery reached 46.93%, an increase of 8.42 percentage points (21.9% relative to condensation alone). The observed non‐monotonic responses to frequency, SPL, and residence time identify an operating window for the tested apparatus. These findings provide an experimental reference for optimizing operating conditions in condensation–acoustic agglomeration systems and support further evaluation for water recovery from representative high‐humidity WFGD gas.

Environmental Progress & Sustainable Energy
China Energy Science and Technology Research Institute Co., Ltd. (China) (CN), Southeast University (CN)
Responsible consumption and production, Clean water and sanitation, Affordable and clean energy, Climate action
Openalex Percentile: Top 25%
Industrial Gas Emission Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Experimental study on water recovery from high‐humidity flue gas using condensation combined with acoustic agglomeration — 胡宇峰, Hengyuan Liu, et al. · Environmental Progress & Sustainable Energy (2026) | TGRS Research Map | TGRS