Tangential volumetric modulated arc therapy reduces cardiac and contralateral low-dose exposure compared with continuous volumetric modulated arc therapy in postoperative breast radiotherapy

Background and purpose Tangential volumetric modulated arc therapy may combine rotational conformality with tangential beam geometry. We compared tangential with continuous-arc volumetric modulated arc therapy for postoperative breast radiotherapy with deliberately matched target coverage, focusing on cardiac and contralateral low-dose exposure. Material and methods Fifty-four patients were included in this paired planning study. For each patient, the clinically delivered tangential plan and a matched continuous-arc plan were evaluated. Target coverage was matched by clinical-target-volume D95% and planning-target-volume D2%. Dose-volume endpoints, low-dose area-under-the-curve metrics, delta dose-volume histograms, subgroup interactions, and mechanistic organ-equivalent-dose surrogates were evaluated. Results Target coverage and homogeneity were comparable, while conformity was higher with tangential planning ( p = 0.006). Tangential planning reduced mean heart dose from 1.34 to 1.17 Gy ( p < 0.001), contralateral lung mean dose from 0.94 to 0.57 Gy, and contralateral breast mean dose from 1.16 to 0.76 Gy (both p < 0.001). Mechanistic organ-equivalent-dose surrogates were reduced by 37.0% for the contralateral lung and 32.7% for the contralateral breast. Exploratory interaction analyses did not identify statistically significant interactions by laterality, deep-inspiration breath hold, simultaneous integrated boost, or regional nodal irradiation. Conclusions In a clinically heterogeneous paired cohort that included boost irradiation, regional nodal irradiation, and deep-inspiration breath hold, tangential volumetric modulated arc therapy reduced cardiac and contralateral low-dose exposure while preserving target coverage.

Authors

Institutions

Publication Details

Journal
Physics and Imaging in Radiation Oncology
Published
2026-11-01
DOI
https://doi.org/10.1016/j.phro.2026.101115
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tangential volumetric modulated arc therapy reduces cardiac and contralateral low-dose exposure compared with continuous volumetric modulated arc therapy in postoperative breast radiotherapy

Jan-Niklas Becker, Daniela Meinecke, Anne Caroline Knöchelmann, Kathrin Burchardt et al.
Physics and Imaging in Radiation Oncology
Advanced Radiotherapy Techniques
article

Tangential volumetric modulated arc therapy reduces cardiac and contralateral low-dose exposure compared with continuous volumetric modulated arc therapy in postoperative breast radiotherapy

Jan-Niklas Becker, Daniela Meinecke, Anne Caroline Knöchelmann, Kathrin Burchardt, Mirko Fischer
article en

Abstract

Background and purpose Tangential volumetric modulated arc therapy may combine rotational conformality with tangential beam geometry. We compared tangential with continuous-arc volumetric modulated arc therapy for postoperative breast radiotherapy with deliberately matched target coverage, focusing on cardiac and contralateral low-dose exposure. Material and methods Fifty-four patients were included in this paired planning study. For each patient, the clinically delivered tangential plan and a matched continuous-arc plan were evaluated. Target coverage was matched by clinical-target-volume D95% and planning-target-volume D2%. Dose-volume endpoints, low-dose area-under-the-curve metrics, delta dose-volume histograms, subgroup interactions, and mechanistic organ-equivalent-dose surrogates were evaluated. Results Target coverage and homogeneity were comparable, while conformity was higher with tangential planning ( p = 0.006). Tangential planning reduced mean heart dose from 1.34 to 1.17 Gy ( p < 0.001), contralateral lung mean dose from 0.94 to 0.57 Gy, and contralateral breast mean dose from 1.16 to 0.76 Gy (both p < 0.001). Mechanistic organ-equivalent-dose surrogates were reduced by 37.0% for the contralateral lung and 32.7% for the contralateral breast. Exploratory interaction analyses did not identify statistically significant interactions by laterality, deep-inspiration breath hold, simultaneous integrated boost, or regional nodal irradiation. Conclusions In a clinically heterogeneous paired cohort that included boost irradiation, regional nodal irradiation, and deep-inspiration breath hold, tangential volumetric modulated arc therapy reduced cardiac and contralateral low-dose exposure while preserving target coverage.

Physics and Imaging in Radiation Oncology
Medizinische Hochschule Hannover (DE)
Openalex Percentile: Top 14%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon