Flexural performance of damaged RC beams strengthened with carbon-, glass-, and steel-fibre-reinforced ferrocement systems

Ferrocement strengthening of reinforced concrete (RC) beams is an effective rehabilitation technique; however, the brittleness of plain mortar and inadequate stress transfer between the mortar, steel mesh, and parent concrete can limit its effectiveness. Although steel fibres provide significant benefits, their susceptibility to corrosion may reduce durability in aggressive environments. To address this issue, this study investigated 15 damaged small-size RC beams strengthened with ferrocement jackets using unreinforced mortar (URM) and mortar incorporating 0.25%, 0.5%, and 1% carbon fibre (CF) and glass fibre (GF) by volume of mortar. For comparison, four additional beams were strengthened using 0.5% and 1% steel fibre (SF). The performance of the strengthened beams was compared with that of four unstrengthened control beams (USBs). In addition, the compressive strength, flexural strength, porosity, and shrinkage properties of the corresponding mortars were evaluated. The results demonstrated significant improvements in the load-deflection behaviour of the strengthened beams. The ultimate load increased by 53% for the URM ferrocement system, 83–100% for CF, 56–86% for GF, and 102–103% for SF compared with the USBs. All fibre-reinforced systems exhibited enhanced post-cracking behaviour and deformation capacity. The flexural strength of the mortar increased by 4–42%, while compressive strength increased by 3–74% for the GF and SF mixes; however, CF reduced compressive strength with increasing fibre content. Fibre incorporation also significantly reduced drying shrinkage despite generally increasing porosity. The results demonstrate that CF and GF can be effectively incorporated into ferrocement strengthening systems to enhance the flexural performance of damaged RC beams while offering the potential advantage of corrosion resistance over conventional steel fibres.

Authors

Institutions

Publication Details

Journal
Construction and Building Materials
Published
2026-11-01
DOI
https://doi.org/10.1016/j.conbuildmat.2026.148756
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexural performance of damaged RC beams strengthened with carbon-, glass-, and steel-fibre-reinforced ferrocement systems

Adewumi John Babafemi, Jeong Gook Jang, Md Jihad Miah, Jack Struthers et al.
Construction and Building Materials
Structural Behavior of Reinforced Concrete
article

Flexural performance of damaged RC beams strengthened with carbon-, glass-, and steel-fibre-reinforced ferrocement systems

Adewumi John Babafemi, Jeong Gook Jang, Md Jihad Miah, Jack Struthers, Muhammad Aminu
article en

Abstract

Ferrocement strengthening of reinforced concrete (RC) beams is an effective rehabilitation technique; however, the brittleness of plain mortar and inadequate stress transfer between the mortar, steel mesh, and parent concrete can limit its effectiveness. Although steel fibres provide significant benefits, their susceptibility to corrosion may reduce durability in aggressive environments. To address this issue, this study investigated 15 damaged small-size RC beams strengthened with ferrocement jackets using unreinforced mortar (URM) and mortar incorporating 0.25%, 0.5%, and 1% carbon fibre (CF) and glass fibre (GF) by volume of mortar. For comparison, four additional beams were strengthened using 0.5% and 1% steel fibre (SF). The performance of the strengthened beams was compared with that of four unstrengthened control beams (USBs). In addition, the compressive strength, flexural strength, porosity, and shrinkage properties of the corresponding mortars were evaluated. The results demonstrated significant improvements in the load-deflection behaviour of the strengthened beams. The ultimate load increased by 53% for the URM ferrocement system, 83–100% for CF, 56–86% for GF, and 102–103% for SF compared with the USBs. All fibre-reinforced systems exhibited enhanced post-cracking behaviour and deformation capacity. The flexural strength of the mortar increased by 4–42%, while compressive strength increased by 3–74% for the GF and SF mixes; however, CF reduced compressive strength with increasing fibre content. Fibre incorporation also significantly reduced drying shrinkage despite generally increasing porosity. The results demonstrate that CF and GF can be effectively incorporated into ferrocement strengthening systems to enhance the flexural performance of damaged RC beams while offering the potential advantage of corrosion resistance over conventional steel fibres.

Construction and Building MaterialsVol. 549
Incheon National University (KR), Stellenbosch University (ZA), University of Brighton (GB)
Openalex Percentile: Top 16%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon