Real-time Volumetric Imaging for Minimally-Invasive Thoracic Interventions: A Deformable Phantom Study
Objectives: This study aimed to evaluate the ability of VoxelMap, a deep learning framework for 3D respiratory motion estimation, to generate volumetric images in real-time from 2D projections acquired for two deformable lung phantoms on a clinical interventional C-arm angiography system. Materials and Methods: VoxelMap was evaluated using the PixelPrint4D and Casper deformable physical thoracic respiratory phantoms. Four-dimensional cone-beam CT (4D CBCT) images acquired on a clinical fixed-room C-arm angiography system were used for network training and volumetric ground truth. Prediction accuracy was evaluated on withheld respiratory phases using structural similarity index measure (SSIM) and peak signalto-noise ratio (PSNR). Model inference time was measured to assess suitability for continuous real-time processing. Deep ensembles were also used to assess model uncertainty. Correlation between ensemble uncertainty and prediction error was evaluated for both phantoms. Results: VoxelMap achieved high prediction accuracy across withheld respiratory phases in both physical phantoms. SSIM values exceeded 0.92 in all experiments, with a higher performance observed for the Casper phantom (0.969-0.973) than for the PixelPrint4D phantom (0.927-0.943). Model inference times were less than 15 ms for both phantoms which is compatible with real-time processing. Ensemble uncertainty was positively correlated with prediction error in both phantoms, indicating that higher uncertainty was associated with less accurate volumetric predictions. Conclusions: Our study demonstrated that VoxelMap generates accurate volumetric deformations of respiratory anatomy from projections acquired on a clinical interventional C-arm system, with computational inference times compatible with continuous processing. By deriving volumetric information directly from two-dimensional fluoroscopic projections, VoxelMap has the potential to augment continuous fluoroscopic guidance with continuously updated volumetric information. Ensemble uncertainty may provide a potentially useful indicator of prediction reliability. Further studies using clinically representative training data and patient studies is required to establish clinical utility. Our code is available at https://github.com/Image-X-Institute/Voxelmap.
Authors
- Magdalena Bazalova‐Carter (ORCID: https://orcid.org/0000-0002-9365-2889)
- Nicholas Hindley (ORCID: https://orcid.org/0000-0003-0162-8716)
- Tess Reynolds (ORCID: https://orcid.org/0000-0003-0543-9170)
- Peter Benjamin Noël (ORCID: https://orcid.org/0000-0002-9671-6171)
- Allen R. Goode (ORCID: https://orcid.org/0000-0002-9475-6671)
- Jessica Y. Im (ORCID: https://orcid.org/0000-0002-6607-872X)
- Alen Biju
- Alexander S Lin (ORCID: https://orcid.org/0009-0002-4601-6000)
Institutions
- The University of Sydney (AU)
- University of Victoria (CA)
- University of Virginia (US)
- University of Pennsylvania (US)
Publication Details
- Journal
- medRxiv
- Published
- 2026-11-02
- DOI
- https://doi.org/10.64898/2026.10.28.26366767
- Primary Topic
- Advanced Radiotherapy Techniques
- Type
- preprint