Electrodeposition of Highly Enriched Uranium Thin Films for Advanced Fission Detectors
Abstract Real-time, in-core neutron flux monitoring is essential for characterizing irradiation conditions in research reactors. Micro-Pocket Fission Detectors (MPFDs) operate as an ionization chamber in which a thin fissile coating electrodeposited onto a platinum substrate generates measurable electrical pulses upon neutron-induced fission, enabling continuous, real-time flux monitoring. Optimal sensor performance requires a deposited uranium mass of 0.3 to 1.0 µg, sufficient to produce a measurable fission rate while remaining thin enough to allow fission fragments to escape into the gas cavity. This article describes the electrodeposition of 93% Highly Enriched Uranium (HEU) onto platinum (Pt) substrates to achieve this target mass, along with a standardized protocol for quantifying the deposited mass using alpha-particle spectrometry. The efficiency of thin-film formation by cyclic voltammetry (CV) was compared to bulk electrolysis (BE) to identify the optimal deposition method. ICP-MS independently validated the radiometric mass calculations. Optimizing both the fabrication and quantification techniques facilitates the development of reliable, high-resolution sensors suitable for deployment in diverse research reactor environments.
Authors
- Harry W. Rollins (ORCID: https://orcid.org/0000-0002-3926-7445)
- Michael A. Reichenberger (ORCID: https://orcid.org/0000-0001-8749-4645)
- Andrew W. Holland
- Brian K. Harris
- Dani Ottaway (ORCID: https://orcid.org/0009-0004-9651-0407)
- Delaney Stine
- Brian W. Miller
- R. Duane Ball
Institutions
- Idaho State University (US)
- Idaho National Laboratory (US)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-02
- DOI
- https://doi.org/10.21203/rs.3.rs-11378166/v1
- Primary Topic
- Radiation Detection and Scintillator Technologies
- Type