Clot Formation in a Blood Bag during a Blood Donation Camp: A Case Report with Root Cause Analysis

Clot formation inside a collected whole blood unit is an uncommon but clinically significant event, as it implicates a deviation from standard collection practices. Any visible clot in a blood component renders the unit unsuitable for transfusion and mandates its discard, according to blood banking quality standards. During a mobile blood donation camp organised by a tertiary care institution, a well-formed clot was identified in a Packed Red Blood Cell (PRBC) unit on routine visual inspection during component preparation. The clot was a firm, red (erythrocyte-rich) thrombus occupying the upper part of the collection bag, without extension into the tubing. The unit was immediately quarantined and discarded. A structured Root Cause Analysis (RCA), comprising staff interviews, timeline reconstruction and record review, was undertaken to identify the most probable contributing factors, since an RCA identifies the most probable root cause of an event rather than establishing definitive causation. Unavailability of an automated Blood Collection Monitor (BCM) during the donation period, which necessitated manual mixing while multiple donors underwent simultaneous phlebotomy, was identified as the most probable root cause, with transient low-flow episodes during collection unable to be excluded in the absence of continuous flow monitoring. Anticoagulant defect, bag/manufacturing defect, tubing obstruction and donor-related hypercoagulability were reviewed and considered unlikely contributors. Corrective measures included retraining staff on continuous manual mixing, careful vein selection for phlebotomy, and revision of camp logistics to prioritise BCM availability at all active bleeding stations. This report highlights the vulnerability of mobile donation settings to delays in mixing and flow monitoring, and underscores the importance of structured RCA and preventive planning in resourcelimited settings.

Authors

Publication Details

Journal
JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH
Published
2026-11-02
DOI
https://doi.org/10.7860/jcdr/2026/89706.24707
Primary Topic
Blood donation and transfusion practices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clot Formation in a Blood Bag during a Blood Donation Camp: A Case Report with Root Cause Analysis

A Ashwin, R Krishnamoorthy, R Niranj Rathan, M Sampath Kumar et al.
2 links
JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH
Blood donation and transfusion practices
article

Clot Formation in a Blood Bag during a Blood Donation Camp: A Case Report with Root Cause Analysis

A Ashwin, R Krishnamoorthy, R Niranj Rathan, M Sampath Kumar, M Aneez Thameema
article en

Abstract

Clot formation inside a collected whole blood unit is an uncommon but clinically significant event, as it implicates a deviation from standard collection practices. Any visible clot in a blood component renders the unit unsuitable for transfusion and mandates its discard, according to blood banking quality standards. During a mobile blood donation camp organised by a tertiary care institution, a well-formed clot was identified in a Packed Red Blood Cell (PRBC) unit on routine visual inspection during component preparation. The clot was a firm, red (erythrocyte-rich) thrombus occupying the upper part of the collection bag, without extension into the tubing. The unit was immediately quarantined and discarded. A structured Root Cause Analysis (RCA), comprising staff interviews, timeline reconstruction and record review, was undertaken to identify the most probable contributing factors, since an RCA identifies the most probable root cause of an event rather than establishing definitive causation. Unavailability of an automated Blood Collection Monitor (BCM) during the donation period, which necessitated manual mixing while multiple donors underwent simultaneous phlebotomy, was identified as the most probable root cause, with transient low-flow episodes during collection unable to be excluded in the absence of continuous flow monitoring. Anticoagulant defect, bag/manufacturing defect, tubing obstruction and donor-related hypercoagulability were reviewed and considered unlikely contributors. Corrective measures included retraining staff on continuous manual mixing, careful vein selection for phlebotomy, and revision of camp logistics to prioritise BCM availability at all active bleeding stations. This report highlights the vulnerability of mobile donation settings to delays in mixing and flow monitoring, and underscores the importance of structured RCA and preventive planning in resourcelimited settings.

JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH
Good health and well-being
Openalex Percentile: Top 11%
Blood donation and transfusion practices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon