Wood Coverings with Integrated Low-Voltage Power Supply for Heating of Nearly Zero Energy Buildings

Wood as a building material is a good thermal insulator, but in thin wood coverings this is not an obstacle to heating when the heating system is placed directly under the top layer. This study investigated the influence of a safety extra-low-voltage power supply (12 V and 24 V) on the surface temperature, response time and heat distribution of wood covering elements with an integrated heating system. Sixteen oak–plywood elements with copper heating wires 3 mm below the walking surface were tested in daily heating cycles; two of them were insulated with reflective foil or aerogel. At 12 V, the surface reached 29.1 ± 0.5 °C (about 5.6 K above ambient), within the comfort limit for floors, while at 24 V it reached 38.6 ± 1.3 °C (p < 0.001) and local checks appeared on the oak surface. The differences between elements were three times larger at 24 V (4.3 K compared with 1.5 K), but the relative non-uniformity was the same (CV of 8.5% at 12 V and 9.0% at 24 V; r = 0.98). Insulation under the element increased the temperature rise of the surface by 15–19%, while the type of insulation had little effect. A 12 V power supply is therefore a safe and sufficient solution for heating with wood coverings in nearly zero energy buildings.

Authors

Publication Details

Journal
Preprints.org
Published
2026-11-02
DOI
https://doi.org/10.20944/preprints202611.0041.v1
Primary Topic
Building energy efficiency and sustainability
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Wood Coverings with Integrated Low-Voltage Power Supply for Heating of Nearly Zero Energy Buildings

Vjekoslav Živković, Josip Miklečić, Andrija Novosel, Tomislav Sedlar
Preprints.org
Building energy efficiency and sustainability
preprint

Wood Coverings with Integrated Low-Voltage Power Supply for Heating of Nearly Zero Energy Buildings

Vjekoslav Živković, Josip Miklečić, Andrija Novosel, Tomislav Sedlar
preprint en

Abstract

Wood as a building material is a good thermal insulator, but in thin wood coverings this is not an obstacle to heating when the heating system is placed directly under the top layer. This study investigated the influence of a safety extra-low-voltage power supply (12 V and 24 V) on the surface temperature, response time and heat distribution of wood covering elements with an integrated heating system. Sixteen oak–plywood elements with copper heating wires 3 mm below the walking surface were tested in daily heating cycles; two of them were insulated with reflective foil or aerogel. At 12 V, the surface reached 29.1 ± 0.5 °C (about 5.6 K above ambient), within the comfort limit for floors, while at 24 V it reached 38.6 ± 1.3 °C (p < 0.001) and local checks appeared on the oak surface. The differences between elements were three times larger at 24 V (4.3 K compared with 1.5 K), but the relative non-uniformity was the same (CV of 8.5% at 12 V and 9.0% at 24 V; r = 0.98). Insulation under the element increased the temperature rise of the surface by 15–19%, while the type of insulation had little effect. A 12 V power supply is therefore a safe and sufficient solution for heating with wood coverings in nearly zero energy buildings.

Preprints.org
Affordable and clean energy
Building energy efficiency and sustainability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon