Software-defined lock-in detection for photoacoustic gas sensing

Introduction Photoacoustic spectroscopy enables compact and selective gas sensing, but its weak acoustic signals require effective phase-sensitive detection. Conventional PAS systems commonly rely on standalone lock-in amplifiers, which separate the demodulation function from excitation generation, sensor control, and data management, limiting system integration and reconfigurability. Methods This work presents a real-time software-defined digital lock-in amplifier that unifies modulation-waveform generation, phase-coherent signal acquisition, quadrature demodulation, configurable filtering, real-time visualization, and data logging within a single LabVIEW application interfaced with a National Instruments USB-6361 data-acquisition module. The S-DLIA was integrated into a CO 2 PAS platform employing a distributed-feedback diode laser at 4992.5157 cm -1 , a differential resonant photoacoustic cell, and second-harmonic wavelength modulation. It was benchmarked against a commercial SR830 lock-in amplifier processing the same photoacoustic signal under matched conditions. Results The sensor responded linearly to CO 2 concentrations from 100 to 1,000 ppm ( R 2 = 0.999). Allan deviation analysis at an integration time of 220 s yielded minimum detection limits of 0.505 ppm for the S-DLIA and 8.909 ppm for the SR830 under the tested configuration, corresponding to a 17.6-fold lower detection limit compared with the SR830. Continuous operation over 24 h at a fixed laboratory location tracked indoor CO 2 variations without apparent drift. Discussion These results validate the S-DLIA as a reconfigurable and flexible alternative to dedicated lock-in instruments in PAS, demonstrating the potential of software-defined synchronous detection for integrated gas-sensing systems.

Authors

Institutions

Publication Details

Journal
Frontiers in Physics
Published
2026-11-02
DOI
https://doi.org/10.3389/fphy.2026.2009327
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Software-defined lock-in detection for photoacoustic gas sensing

Jintao Wu, Lei Dong, Ruyue Cui, Yaoxin Wang et al.
Frontiers in Physics
Spectroscopy and Laser Applications
article

Software-defined lock-in detection for photoacoustic gas sensing

Jintao Wu, Lei Dong, Ruyue Cui, Yaoxin Wang, Chenglong Wang, Hongpeng Wu, Shurong Guo, Yanan Su, Chaofeng Sun, Chunhong Zhao
article en

Abstract

Introduction Photoacoustic spectroscopy enables compact and selective gas sensing, but its weak acoustic signals require effective phase-sensitive detection. Conventional PAS systems commonly rely on standalone lock-in amplifiers, which separate the demodulation function from excitation generation, sensor control, and data management, limiting system integration and reconfigurability. Methods This work presents a real-time software-defined digital lock-in amplifier that unifies modulation-waveform generation, phase-coherent signal acquisition, quadrature demodulation, configurable filtering, real-time visualization, and data logging within a single LabVIEW application interfaced with a National Instruments USB-6361 data-acquisition module. The S-DLIA was integrated into a CO 2 PAS platform employing a distributed-feedback diode laser at 4992.5157 cm -1 , a differential resonant photoacoustic cell, and second-harmonic wavelength modulation. It was benchmarked against a commercial SR830 lock-in amplifier processing the same photoacoustic signal under matched conditions. Results The sensor responded linearly to CO 2 concentrations from 100 to 1,000 ppm ( R 2 = 0.999). Allan deviation analysis at an integration time of 220 s yielded minimum detection limits of 0.505 ppm for the S-DLIA and 8.909 ppm for the SR830 under the tested configuration, corresponding to a 17.6-fold lower detection limit compared with the SR830. Continuous operation over 24 h at a fixed laboratory location tracked indoor CO 2 variations without apparent drift. Discussion These results validate the S-DLIA as a reconfigurable and flexible alternative to dedicated lock-in instruments in PAS, demonstrating the potential of software-defined synchronous detection for integrated gas-sensing systems.

Frontiers in PhysicsVol. 14
Shanxi University (CN)
Openalex Percentile: Top 29%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon