Comparison between applanation tonometry and rebound tonometry in different body positions

Abstract Background To compare applanation and rebound tonometry in different body positions and assess the reliability and repeatability of clinician-measured and self-measured intraocular pressure (IOP). Methods Sixty-four glaucoma patients and glaucoma suspects underwent two consecutive IOP measurements using Goldmann applanation tonometry (GAT), iCare IC200 and self-tonometry with iCare HOME2 in seated position, and two measurements in supine position with Perkins tonometry (PAT), iCare IC200 and iCare HOME2. Central corneal thickness (CCT), lens status and other clinical variables were recorded. Agreement, repeatability, and the influence of CCT were evaluated using Bland–Altman analysis, paired t-tests, and linear regression. Results iCare HOME2 showed excellent agreement with applanation tonometry (mean difference: −0.39 mmHg seated, − 0.33 mmHg supine; both p > 0.05). iCare IC200 consistently overestimated IOP (− 0.68 mmHg vs. GAT, − 1.94 mmHg vs. PAT; p < 0.05), with a non-significant but evident trend toward increased overestimation at higher IOP levels. All devices demonstrated high repeatability in both positions (absolute Limits of Repeatability ≤ 2.73 mmHg). A negative correlation was found between CCT and IOP difference, indicating greater overestimation by rebound tonometers, particularly iCare IC200, in thicker corneas. Conclusions Rebound tonometry, especially iCare HOME2, offers reliable and repeatable IOP measurements across body positions and may represent a practical tool for self-monitoring, including in non-standard settings. CCT and IOP levels should be considered when interpreting rebound readings.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-02
DOI
https://doi.org/10.21203/rs.3.rs-11378531/v1
Primary Topic
Glaucoma and retinal disorders
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Comparison between applanation tonometry and rebound tonometry in different body positions

Benedetta Colizzi, Dario Romano, Luca Mario Rossetti, Amir Ali Aminoleslami
1 links
Research Square
Glaucoma and retinal disorders
preprint

Comparison between applanation tonometry and rebound tonometry in different body positions

Benedetta Colizzi, Dario Romano, Luca Mario Rossetti, Amir Ali Aminoleslami
preprint en

Abstract

Abstract Background To compare applanation and rebound tonometry in different body positions and assess the reliability and repeatability of clinician-measured and self-measured intraocular pressure (IOP). Methods Sixty-four glaucoma patients and glaucoma suspects underwent two consecutive IOP measurements using Goldmann applanation tonometry (GAT), iCare IC200 and self-tonometry with iCare HOME2 in seated position, and two measurements in supine position with Perkins tonometry (PAT), iCare IC200 and iCare HOME2. Central corneal thickness (CCT), lens status and other clinical variables were recorded. Agreement, repeatability, and the influence of CCT were evaluated using Bland–Altman analysis, paired t-tests, and linear regression. Results iCare HOME2 showed excellent agreement with applanation tonometry (mean difference: −0.39 mmHg seated, − 0.33 mmHg supine; both p > 0.05). iCare IC200 consistently overestimated IOP (− 0.68 mmHg vs. GAT, − 1.94 mmHg vs. PAT; p < 0.05), with a non-significant but evident trend toward increased overestimation at higher IOP levels. All devices demonstrated high repeatability in both positions (absolute Limits of Repeatability ≤ 2.73 mmHg). A negative correlation was found between CCT and IOP difference, indicating greater overestimation by rebound tonometers, particularly iCare IC200, in thicker corneas. Conclusions Rebound tonometry, especially iCare HOME2, offers reliable and repeatable IOP measurements across body positions and may represent a practical tool for self-monitoring, including in non-standard settings. CCT and IOP levels should be considered when interpreting rebound readings.

Research Square
University of Milan (IT), Azienda Socio Sanitaria Territoriale Santi Paolo e Carlo (IT)
Good health and well-being
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Comparison between applanation tonometry and rebound tonometry in different body positions — Benedetta Colizzi, Dario Romano, et al. · Research Square (2026) | TGRS Research Map | TGRS