Distillation-Assisted Determination of Ethanol in Exhaled Breath Using an Oxygen-Enhanced Gas Curtain Plasma (GCP) Ion Source with High-Field Asymmetric Ion Mobility Spectrometry (FAIMS)

Recent progress in exhaled breath analysis offers a promising noninvasive alternative to blood sampling for clinical and forensic applications. This study presents an oxygen-enhanced gas curtain plasma (GCP) ion source coupled with high-field asymmetric ion mobility spectrometry (FAIMS) for detecting breath alcohol. Exhaled breath condensates were collected from six fasting volunteers before and six hours after alcohol intake, then analyzed by direct GCP-FAIMS and micro-distillation, with mass spectrometry for verification. After alcohol ingestion, the intensity of the ethanol radical cation [C2H5OH]+ (m/z 46) significantly increased from 3 cps to 34 cps, accompanied by enhanced signals of related ions including [NH4+·H2O]+ (m/z 36) and [C4H8O]+ (m/z 72). Micro-distillation further improved spectral clarity and revealed well-resolved ethanol monomer and dimer ions, with compensation voltages matching ethanol standards, confirming impurity removal. The coupled system exhibited good detection sensitivity with a limit of detection (LOD) of 0.318 ppm (m/v) for the protonated ethanol dimer, a limit of quantification (LOQ) of 1.059 ppm (m/v), and a correlation coefficient (R2) of 0.9843. The method also showed good reproducibility with a relative standard deviation of 13.2% for the ethanol monomer signal and 6.5% for the [NH4+·H2O]+ signal. These results demonstrate the proof-of-concept feasibility of the oxygen-enhanced GCP-FAIMS system for ethanol detection in exhaled breath condensate, supporting further development for noninvasive breath alcohol screening.

Authors

Institutions

Publication Details

Journal
Analytical Letters
Published
2026-11-02
DOI
https://doi.org/10.1080/00032719.2026.2756603
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Distillation-Assisted Determination of Ethanol in Exhaled Breath Using an Oxygen-Enhanced Gas Curtain Plasma (GCP) Ion Source with High-Field Asymmetric Ion Mobility Spectrometry (FAIMS)

Huan Chen, Yinghao Li, Yafeng Liu, Hua Li
Analytical Letters
Mass Spectrometry Techniques and Applications
article

Distillation-Assisted Determination of Ethanol in Exhaled Breath Using an Oxygen-Enhanced Gas Curtain Plasma (GCP) Ion Source with High-Field Asymmetric Ion Mobility Spectrometry (FAIMS)

Huan Chen, Yinghao Li, Yafeng Liu, Hua Li
article en

Abstract

Recent progress in exhaled breath analysis offers a promising noninvasive alternative to blood sampling for clinical and forensic applications. This study presents an oxygen-enhanced gas curtain plasma (GCP) ion source coupled with high-field asymmetric ion mobility spectrometry (FAIMS) for detecting breath alcohol. Exhaled breath condensates were collected from six fasting volunteers before and six hours after alcohol intake, then analyzed by direct GCP-FAIMS and micro-distillation, with mass spectrometry for verification. After alcohol ingestion, the intensity of the ethanol radical cation [C2H5OH]+ (m/z 46) significantly increased from 3 cps to 34 cps, accompanied by enhanced signals of related ions including [NH4+·H2O]+ (m/z 36) and [C4H8O]+ (m/z 72). Micro-distillation further improved spectral clarity and revealed well-resolved ethanol monomer and dimer ions, with compensation voltages matching ethanol standards, confirming impurity removal. The coupled system exhibited good detection sensitivity with a limit of detection (LOD) of 0.318 ppm (m/v) for the protonated ethanol dimer, a limit of quantification (LOQ) of 1.059 ppm (m/v), and a correlation coefficient (R2) of 0.9843. The method also showed good reproducibility with a relative standard deviation of 13.2% for the ethanol monomer signal and 6.5% for the [NH4+·H2O]+ signal. These results demonstrate the proof-of-concept feasibility of the oxygen-enhanced GCP-FAIMS system for ethanol detection in exhaled breath condensate, supporting further development for noninvasive breath alcohol screening.

Analytical Letters
Guilin University of Electronic Technology (CN)
Good health and well-being
Openalex Percentile: Top 29%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon