Autonomous paper valves using PDMS vacuum pumps as actuators for colorimetric chrono-sampling

a thin polymeric membrane. The pump-membrane system was experimentally characterized and used to parameterize numerical simulations, allowing predictive optimization of device performance. As a proof of concept, we demonstrate autonomous monitoring of culture medium pH at four successive time points separated by 45 minutes, with the temporal pH profile obtained from a single image acquired at the end of the experiment. This approach can be readily extended to other sampling intervals and sensor types, leveraging the inherent tunability of PDMS-based systems. Overall, this autonomous chrono-sampling platform enables low-cost, instrument-free, and temporally controlled assays, with potential applications in point-of-care diagnostics, cell culture, environmental monitoring, and time-resolved biochemical analyses.

Authors

Institutions

Publication Details

Journal
Lab on a Chip
Published
2026-11-18
DOI
https://doi.org/10.1039/d6lc00389c
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Autonomous paper valves using PDMS vacuum pumps as actuators for colorimetric chrono-sampling

Franco Nicolas Nazar, Lourdes Basabe‐Desmonts, Pablo E. Guevara‐Pantoja, Fernando Benito‐Lopez et al.
1 links
Lab on a Chip
Microfluidic and Capillary Electrophoresis Applications
article

Autonomous paper valves using PDMS vacuum pumps as actuators for colorimetric chrono-sampling

Franco Nicolas Nazar, Lourdes Basabe‐Desmonts, Pablo E. Guevara‐Pantoja, Fernando Benito‐Lopez, Idoia Postigo
article en

Abstract

a thin polymeric membrane. The pump-membrane system was experimentally characterized and used to parameterize numerical simulations, allowing predictive optimization of device performance. As a proof of concept, we demonstrate autonomous monitoring of culture medium pH at four successive time points separated by 45 minutes, with the temporal pH profile obtained from a single image acquired at the end of the experiment. This approach can be readily extended to other sampling intervals and sensor types, leveraging the inherent tunability of PDMS-based systems. Overall, this autonomous chrono-sampling platform enables low-cost, instrument-free, and temporally controlled assays, with potential applications in point-of-care diagnostics, cell culture, environmental monitoring, and time-resolved biochemical analyses.

Lab on a Chip
Ikerbasque (ES), University of the Basque Country (ES)
Ministerio de Ciencia, Innovación y Universidades, Eusko Jaurlaritza, Agencia Estatal de Investigación, H2020 Marie Skłodowska-Curie Actions
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon