Lower Abdominal Fat Reduction After a Diluted Deoxycholic Acid-Based Injection Protocol: Preliminary Findings from a Five-Patient Case Series

Background: Deoxycholic acid (DCA) causes adipocytolysis after subcutaneous injection and is approved for reducing submental fat. Use in the abdomen is off-label, and evidence for low-concentration, cannula-delivered protocols remains limited. Objective: Our objective is to describe clinical and ultrasound outcomes after a diluted DCA-based injection protocol for localized lower abdominal adiposity. Methods: Five healthy adult women aged 31–43 years underwent two lower-abdominal treatments 4 weeks apart. For each treatment, two 2 mL vials of DCA 10 mg/mL were diluted to a final concentration of 2 mg/mL using L-carnitine and a clinic-prepared tumescent solution, yielding 20 mL of total injectate. The formulation was delivered into the subcutaneous layer using a 23-gauge, 50 mm cannula. Body weight, abdominal circumference, caliper thickness, clinical photographs, and ultrasound-measured local tissue depth were reviewed at baseline and final follow-up; caliper thickness and circumference were also recorded at interim visits. Results: All five cases showed reductions in both caliper thickness and ultrasound-measured local tissue depth. Mean caliper thickness decreased from 41.14 ± 4.76 mm to 35.94 ± 5.15 mm, a mean reduction of 5.20 ± 1.20 mm. Mean ultrasound depth decreased from 3.22 ± 0.80 cm to 2.39 ± 0.81 cm, a mean reduction of 0.83 ± 0.15 cm; the mean individual relative reduction was 27.5%. Mean body weight changed by −0.08 kg and mean abdominal circumference by −0.64 cm, with substantial case-to-case variability. The available summary reported procedural pain scores of 0–1 on a 10-point visual analog scale; complete patient-level adverse-event records were unavailable, precluding systematic safety assessment. Conclusion: In this exploratory five-patient series, localized caliper and ultrasound tissue-depth measures decreased after two sessions of a 2 mg/mL diluted DCA-based protocol despite variable changes in body weight and circumference. The uncontrolled design, combined formulation, small sample, and incomplete safety documentation preclude attribution of effect to DCA alone. Controlled studies with standardized imaging and complete adverse-event capture are required.

Authors

Institutions

Publication Details

Journal
Life
Published
2026-11-01
DOI
https://doi.org/10.3390/life16111857
Primary Topic
Body Contouring and Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lower Abdominal Fat Reduction After a Diluted Deoxycholic Acid-Based Injection Protocol: Preliminary Findings from a Five-Patient Case Series

Kyu‐Ho Yi, Kyungtae T Bae, Jin Hyun Kim
Life
Body Contouring and Surgery
article

Lower Abdominal Fat Reduction After a Diluted Deoxycholic Acid-Based Injection Protocol: Preliminary Findings from a Five-Patient Case Series

Kyu‐Ho Yi, Kyungtae T Bae, Jin Hyun Kim
article en

Abstract

Background: Deoxycholic acid (DCA) causes adipocytolysis after subcutaneous injection and is approved for reducing submental fat. Use in the abdomen is off-label, and evidence for low-concentration, cannula-delivered protocols remains limited. Objective: Our objective is to describe clinical and ultrasound outcomes after a diluted DCA-based injection protocol for localized lower abdominal adiposity. Methods: Five healthy adult women aged 31–43 years underwent two lower-abdominal treatments 4 weeks apart. For each treatment, two 2 mL vials of DCA 10 mg/mL were diluted to a final concentration of 2 mg/mL using L-carnitine and a clinic-prepared tumescent solution, yielding 20 mL of total injectate. The formulation was delivered into the subcutaneous layer using a 23-gauge, 50 mm cannula. Body weight, abdominal circumference, caliper thickness, clinical photographs, and ultrasound-measured local tissue depth were reviewed at baseline and final follow-up; caliper thickness and circumference were also recorded at interim visits. Results: All five cases showed reductions in both caliper thickness and ultrasound-measured local tissue depth. Mean caliper thickness decreased from 41.14 ± 4.76 mm to 35.94 ± 5.15 mm, a mean reduction of 5.20 ± 1.20 mm. Mean ultrasound depth decreased from 3.22 ± 0.80 cm to 2.39 ± 0.81 cm, a mean reduction of 0.83 ± 0.15 cm; the mean individual relative reduction was 27.5%. Mean body weight changed by −0.08 kg and mean abdominal circumference by −0.64 cm, with substantial case-to-case variability. The available summary reported procedural pain scores of 0–1 on a 10-point visual analog scale; complete patient-level adverse-event records were unavailable, precluding systematic safety assessment. Conclusion: In this exploratory five-patient series, localized caliper and ultrasound tissue-depth measures decreased after two sessions of a 2 mg/mL diluted DCA-based protocol despite variable changes in body weight and circumference. The uncontrolled design, combined formulation, small sample, and incomplete safety documentation preclude attribution of effect to DCA alone. Controlled studies with standardized imaging and complete adverse-event capture are required.

LifeVol. 16(11)
Samsung (South Korea) (KR), Yonsei University College of Dentistry (KR)
Openalex Percentile: Top 10%
Body Contouring and Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon