Comparison of 3 Headless Compression Screw Types for Proximal, Waist, and Distal Scaphoid Fractures

Introduction: Headless compression screws are a popular fixation construct for scaphoid fractures as they can maintain reduction and provide fracture compression without implant prominence. The purpose of this study is to characterize fracture compression in models of proximal, waist, and distal scaphoid fractures for 3 types of headless compression screws. Methods: Three Sawbones models representing proximal, waist, and distal fractures were used to test the biomechanical properties of three 20-mm screws (Acumed Acutrak 3 Mini, Arthrex Compression FT Mini, Medartis Cannulated HD10). Screws were inserted in an antegrade fashion at a rate of 30 rpm using a DC motor mounted to the actuator of an Instron load frame. Compressive force was recorded at the point of flush insertion and compared using analysis of variance and Student t test. Results: Acutrak 3 achieved the highest compression in models of proximal and waist fractures, and the Acutrak 3 and Arthrex FT screws demonstrated similar compression in models of distal fractures with antegrade insertion. Both the Acutrak 3 and Arthrex FT screws demonstrated significantly less compression in distal fractures when compared with proximal and waist fractures. Conclusions: As measured at the flush insertion point, the Acutrak 3 screw demonstrated the highest compressive force for models of proximal and waist fractures. Fully threaded variable pitch screw design resulted in greater simulated fracture compression than Herbert-style screws, which do not have central threads. Understanding the interplay of screw characteristics with various fracture patterns is important when selecting an operative construct that optimizes fracture stability.

Authors

Institutions

Publication Details

Journal
Hand
Published
2026-11-01
DOI
https://doi.org/10.1177/15589447261497445
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of 3 Headless Compression Screw Types for Proximal, Waist, and Distal Scaphoid Fractures

Eric R. Wagner, Joanne Y. Zhou, Spencer B. Chambers, Michael Brandon Gottschalk et al.
Hand
Orthopedic Surgery and Rehabilitation
article

Comparison of 3 Headless Compression Screw Types for Proximal, Waist, and Distal Scaphoid Fractures

Eric R. Wagner, Joanne Y. Zhou, Spencer B. Chambers, Michael Brandon Gottschalk, Nina Suh, James Thompson
article en

Abstract

Introduction: Headless compression screws are a popular fixation construct for scaphoid fractures as they can maintain reduction and provide fracture compression without implant prominence. The purpose of this study is to characterize fracture compression in models of proximal, waist, and distal scaphoid fractures for 3 types of headless compression screws. Methods: Three Sawbones models representing proximal, waist, and distal fractures were used to test the biomechanical properties of three 20-mm screws (Acumed Acutrak 3 Mini, Arthrex Compression FT Mini, Medartis Cannulated HD10). Screws were inserted in an antegrade fashion at a rate of 30 rpm using a DC motor mounted to the actuator of an Instron load frame. Compressive force was recorded at the point of flush insertion and compared using analysis of variance and Student t test. Results: Acutrak 3 achieved the highest compression in models of proximal and waist fractures, and the Acutrak 3 and Arthrex FT screws demonstrated similar compression in models of distal fractures with antegrade insertion. Both the Acutrak 3 and Arthrex FT screws demonstrated significantly less compression in distal fractures when compared with proximal and waist fractures. Conclusions: As measured at the flush insertion point, the Acutrak 3 screw demonstrated the highest compressive force for models of proximal and waist fractures. Fully threaded variable pitch screw design resulted in greater simulated fracture compression than Herbert-style screws, which do not have central threads. Understanding the interplay of screw characteristics with various fracture patterns is important when selecting an operative construct that optimizes fracture stability.

Hand
Emory University (US), St. Joseph's Hospital (CA), The University of Texas Health Science Center at Houston (US)
Openalex Percentile: Top 10%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon