High Diagnostic Yield of Testing With a Diabetes Device Screening Series in Patients With Suspected Allergic Reactions to Glucose Sensors, Insulin Patch Pumps and Insulin Infusion Sets

BACKGROUND: Patch testing in patients with dermatitis from diabetes devices is challenging because device composition is nearly always undisclosed, relevant allergens are incompletely known, and many suspected allergens are not commercially available. OBJECTIVES: To evaluate the diagnostic yield of a dedicated diabetes device screening series, supplemented with a (meth)acrylate series and testing of patients' own device adhesives and adhesive extracts, in patients with suspected allergic contact dermatitis to glucose sensors, insulin patch pumps, or infusion sets. MATERIALS AND METHODS: We performed a retrospective patch test study of 100 patients referred to a tertiary referral centre for suspected allergic reactions to diabetes devices. RESULTS: Seventy-one patients reacted to one or more allergens in the diabetes device screening series; in 50 (70.4%), at least one reaction was clinically relevant. The most frequent relevant allergens were colophonium and its related substances abietic acid and hydroabietyl alcohol, isobornyl acrylate, dicyclohexylmethane-4,4'-diisocyanate, and N,N-dimethylacrylamide. The (meth)acrylate series had no clear additional diagnostic value. Testing with patients' own device adhesives and extracts frequently identified allergic reactions to devices not recognised by the results of the screening series alone. CONCLUSION: The combined approach identified relevant contact allergies in most patients with suspected allergic contact dermatitis to diabetes devices.

Authors

Institutions

Publication Details

Journal
Contact Dermatitis
Published
2026-11-02
DOI
https://doi.org/10.1111/cod.70275
Primary Topic
Contact Dermatitis and Allergies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High Diagnostic Yield of Testing With a Diabetes Device Screening Series in Patients With Suspected Allergic Reactions to Glucose Sensors, Insulin Patch Pumps and Insulin Infusion Sets

Thomas Rustemeyer, Norbertus Anton Ipenburg, Anton C. de Groot, Emma M. van Oers et al.
2 links
Contact Dermatitis
Contact Dermatitis and Allergies
article

High Diagnostic Yield of Testing With a Diabetes Device Screening Series in Patients With Suspected Allergic Reactions to Glucose Sensors, Insulin Patch Pumps and Insulin Infusion Sets

Thomas Rustemeyer, Norbertus Anton Ipenburg, Anton C. de Groot, Emma M. van Oers, Mounir Yaâkoubi
article en

Abstract

BACKGROUND: Patch testing in patients with dermatitis from diabetes devices is challenging because device composition is nearly always undisclosed, relevant allergens are incompletely known, and many suspected allergens are not commercially available. OBJECTIVES: To evaluate the diagnostic yield of a dedicated diabetes device screening series, supplemented with a (meth)acrylate series and testing of patients' own device adhesives and adhesive extracts, in patients with suspected allergic contact dermatitis to glucose sensors, insulin patch pumps, or infusion sets. MATERIALS AND METHODS: We performed a retrospective patch test study of 100 patients referred to a tertiary referral centre for suspected allergic reactions to diabetes devices. RESULTS: Seventy-one patients reacted to one or more allergens in the diabetes device screening series; in 50 (70.4%), at least one reaction was clinically relevant. The most frequent relevant allergens were colophonium and its related substances abietic acid and hydroabietyl alcohol, isobornyl acrylate, dicyclohexylmethane-4,4'-diisocyanate, and N,N-dimethylacrylamide. The (meth)acrylate series had no clear additional diagnostic value. Testing with patients' own device adhesives and extracts frequently identified allergic reactions to devices not recognised by the results of the screening series alone. CONCLUSION: The combined approach identified relevant contact allergies in most patients with suspected allergic contact dermatitis to diabetes devices.

Contact Dermatitis
Amsterdam University Medical Centers (NL)
Good health and well-being
Openalex Percentile: Top 12%
Contact Dermatitis and Allergies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
High Diagnostic Yield of Testing With a Diabetes Device Screening Series in Patients With Suspected Allergic Reactions to Glucose Sensors, Insulin Patch Pumps and Insulin Infusion Sets — Thomas Rustemeyer, Norbertus Anton Ipenburg, et al. · Contact Dermatitis (2026) | TGRS Research Map | TGRS