EVALUATION OF IODINE AND CALCIUM CT NUMBER IN DUAL-ENERGY COMPUTED TOMOGRAPHY (DECT) USING A FABRICATED IN-HOUSE PHANTOM

The aim of this study was to develop an in-house phantom with inserts of iodine and calcium materials for evaluating the accuracy of CT numbers from virtual monochromatic image (VMI) of DECT. The phantom was made from polyester resin (PESR) mixed with methyl ethyl ketone peroxide (MEKP) as catalyst in a ratio of 300:1, with a 16 cm diameter and 5 cm height. The phantom had 10 holes, each with a diameter of 1.5 cm. Each hole was filled with water, air, iodine (with various concentrations of 5, 7.5, 10, and 15 mg/ml), and calcium (with various concentrations of 200, 300, 500, and 600 mg/ml). The phantom was scanned by an Ultrafast kV Switching DECT with a tube voltage of 80/140 kV, slice thickness of 5 mm, rotation time of 0.5 s, and tube current variations (200, 250, 300, 335, and 370 mA). Images were reconstructed to a VMI at 50, 70, and 100 keV. The CT number accuracy of VMI images was measured using IndoQCT software. Absolute percentage error (APE) was calculated from measured CT numbers and standard phantom. We found that the changes in CT numbers of iodine and calcium showed the same trend. The CT numbers for both iodine and calcium slightly increased with higher tube currents. The CT number decreased by 1.5-3 times from an energy of 50 to 100 keV. For all concentrations, the APE of CT numbers of the in-house phantom were <32% and <25% compared to the standard for iodine and calcium, respectively.

Authors

Institutions

Publication Details

Journal
Jurnal Teknologi
Published
2026-11-01
DOI
https://doi.org/10.11113/jurnalteknologi.v88.25139
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EVALUATION OF IODINE AND CALCIUM CT NUMBER IN DUAL-ENERGY COMPUTED TOMOGRAPHY (DECT) USING A FABRICATED IN-HOUSE PHANTOM

Pingki S. Dewi, Ariij Naufal, Choirul Anam, Ilham Alkian et al.
Jurnal Teknologi
Advanced X-ray and CT Imaging
article

EVALUATION OF IODINE AND CALCIUM CT NUMBER IN DUAL-ENERGY COMPUTED TOMOGRAPHY (DECT) USING A FABRICATED IN-HOUSE PHANTOM

Pingki S. Dewi, Ariij Naufal, Choirul Anam, Ilham Alkian, Geoff Dougherty, Heri Sutanto, Adiwasono M. B. Setiawan
article en

Abstract

The aim of this study was to develop an in-house phantom with inserts of iodine and calcium materials for evaluating the accuracy of CT numbers from virtual monochromatic image (VMI) of DECT. The phantom was made from polyester resin (PESR) mixed with methyl ethyl ketone peroxide (MEKP) as catalyst in a ratio of 300:1, with a 16 cm diameter and 5 cm height. The phantom had 10 holes, each with a diameter of 1.5 cm. Each hole was filled with water, air, iodine (with various concentrations of 5, 7.5, 10, and 15 mg/ml), and calcium (with various concentrations of 200, 300, 500, and 600 mg/ml). The phantom was scanned by an Ultrafast kV Switching DECT with a tube voltage of 80/140 kV, slice thickness of 5 mm, rotation time of 0.5 s, and tube current variations (200, 250, 300, 335, and 370 mA). Images were reconstructed to a VMI at 50, 70, and 100 keV. The CT number accuracy of VMI images was measured using IndoQCT software. Absolute percentage error (APE) was calculated from measured CT numbers and standard phantom. We found that the changes in CT numbers of iodine and calcium showed the same trend. The CT numbers for both iodine and calcium slightly increased with higher tube currents. The CT number decreased by 1.5-3 times from an energy of 50 to 100 keV. For all concentrations, the APE of CT numbers of the in-house phantom were <32% and <25% compared to the standard for iodine and calcium, respectively.

Jurnal TeknologiVol. 88(6)
Diponegoro University (ID), California State University, Channel Islands (US)
Openalex Percentile: Top 25%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
EVALUATION OF IODINE AND CALCIUM CT NUMBER IN DUAL-ENERGY COMPUTED TOMOGRAPHY (DECT) USING A FABRICATED IN-HOUSE PHANTOM — Pingki S. Dewi, Ariij Naufal, et al. · Jurnal Teknologi (2026) | TGRS Research Map | TGRS