Stacking machine learning model with enhanced DWT features for detection and classification of power quality disturbances in EV charging stations

The rapid increase in the use of electric vehicles has led to the establishment of charging stations across the power grid. Although electric vehicle charging stations provide significant social benefits and convenient access to charging services, their integration into the power grid may introduce challenges related to protection and power quality disturbances. Therefore, accurate detection of power quality disturbances is crucial to prevent equipment damage and ensure reliable operation. For this purpose, this paper proposed a framework based on an enhanced Discrete Wavelet Transform (DWT) for feature extraction and a stacking Machine Learning (ML) model to detect power quality disturbances in electric vehicle charging stations. In this paper, feature extraction has been performed using the DWT with the db4 smooth Mother Wavelet (MW) to mitigate the problem of high energy at the beginning and end of the time window in the DWT with the db4 MW, and enhance focus on the actual disturbance interval. Furthermore, a stacking ML model has been proposed to improve overall detection accuracy. To assess robustness, the proposed framework is further evaluated under multiple practical variations, including different noise levels, sampling rates, DWT decomposition levels, and real-world data from a charging station The proposed framework achieved an outstanding detection and classification accuracy, particularly in the presence of complex power quality disturbances. The results are compared to various state-of-the-art methods and evaluated using multiple evaluation metrics, confirming the reliability and excellent performance of the proposed approach.

Authors

Institutions

Publication Details

Journal
Energy Reports
Published
2026-11-01
DOI
https://doi.org/10.1016/j.egyr.2026.109825
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stacking machine learning model with enhanced DWT features for detection and classification of power quality disturbances in EV charging stations

Hamid Reza Baghaee, Hassan Sam Daliri, Hamed Nafisi, Hossein Askarian Abyaneh et al.
3 links
Energy Reports
Power Quality and Harmonics
article

Stacking machine learning model with enhanced DWT features for detection and classification of power quality disturbances in EV charging stations

Hamid Reza Baghaee, Hassan Sam Daliri, Hamed Nafisi, Hossein Askarian Abyaneh, Mohadese Dejagah
article en

Abstract

The rapid increase in the use of electric vehicles has led to the establishment of charging stations across the power grid. Although electric vehicle charging stations provide significant social benefits and convenient access to charging services, their integration into the power grid may introduce challenges related to protection and power quality disturbances. Therefore, accurate detection of power quality disturbances is crucial to prevent equipment damage and ensure reliable operation. For this purpose, this paper proposed a framework based on an enhanced Discrete Wavelet Transform (DWT) for feature extraction and a stacking Machine Learning (ML) model to detect power quality disturbances in electric vehicle charging stations. In this paper, feature extraction has been performed using the DWT with the db4 smooth Mother Wavelet (MW) to mitigate the problem of high energy at the beginning and end of the time window in the DWT with the db4 MW, and enhance focus on the actual disturbance interval. Furthermore, a stacking ML model has been proposed to improve overall detection accuracy. To assess robustness, the proposed framework is further evaluated under multiple practical variations, including different noise levels, sampling rates, DWT decomposition levels, and real-world data from a charging station The proposed framework achieved an outstanding detection and classification accuracy, particularly in the presence of complex power quality disturbances. The results are compared to various state-of-the-art methods and evaluated using multiple evaluation metrics, confirming the reliability and excellent performance of the proposed approach.

Energy ReportsVol. 16
Tarbiat Modares University (IR), Amirkabir University of Technology (IR)
Affordable and clean energy, Industry, innovation and infrastructure
Openalex Percentile: Top 24%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon