ANALYTICAL METHOD AND VALIDATION FOR DETERMINATION OF ELINZANETANT IN BULK FORM AND MARKETED PHARMACEUTICAL DOSAGE FORM BY USING RP-HPLC

An efficient and simple RP-HPLC method has been developed and validated for the estimation of Elinzanetant in bulk and marketed pharmaceutical dosage forms. The mobile phase used for the chromatographic runs consisted of Methanol and Phosphate buffer (0.02M, pH-3.6) in the ratio of 40:60% v/v. The separation was achieved on an Inertsil C18 ODS (4.6mm × 250mm) 5µm particle size column using isocratic mode. Drug peak were well separated and were detected by a UV detector at 246 nm. The retention time of Elinzanetant was found to be 5.462minutes. The method was linear at the concentration range 6–14 μg/ml for Elinzanetant. The method has been validated according to ICH guidelines with respect to system suitability, specificity, precision, accuracy and robustness. Elinzanetant limit of detection (LOD) and limit of quantification (LOQ) were 0.487μg/ml and 1.477μg/ml respectively. Keywords: Elinzanetant, RP-HPLC, Accuracy, Precision, Robustness, ICH Guidelines.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-01
DOI
https://doi.org/10.5281/zenodo.23862137
Primary Topic
Analytical Methods in Pharmaceuticals
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

ANALYTICAL METHOD AND VALIDATION FOR DETERMINATION OF ELINZANETANT IN BULK FORM AND MARKETED PHARMACEUTICAL DOSAGE FORM BY USING RP-HPLC

Narra Kavitha*, Gunnakolu Anusha, V. Anuja Kumari, Erla Arun, Nakka Balakrishna, Kavali Bhanu Prakash
3 links
Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
preprint

ANALYTICAL METHOD AND VALIDATION FOR DETERMINATION OF ELINZANETANT IN BULK FORM AND MARKETED PHARMACEUTICAL DOSAGE FORM BY USING RP-HPLC

Narra Kavitha*, Gunnakolu Anusha, V. Anuja Kumari, Erla Arun, Nakka Balakrishna, Kavali Bhanu Prakash
preprint en

Abstract

An efficient and simple RP-HPLC method has been developed and validated for the estimation of Elinzanetant in bulk and marketed pharmaceutical dosage forms. The mobile phase used for the chromatographic runs consisted of Methanol and Phosphate buffer (0.02M, pH-3.6) in the ratio of 40:60% v/v. The separation was achieved on an Inertsil C18 ODS (4.6mm × 250mm) 5µm particle size column using isocratic mode. Drug peak were well separated and were detected by a UV detector at 246 nm. The retention time of Elinzanetant was found to be 5.462minutes. The method was linear at the concentration range 6–14 μg/ml for Elinzanetant. The method has been validated according to ICH guidelines with respect to system suitability, specificity, precision, accuracy and robustness. Elinzanetant limit of detection (LOD) and limit of quantification (LOQ) were 0.487μg/ml and 1.477μg/ml respectively. Keywords: Elinzanetant, RP-HPLC, Accuracy, Precision, Robustness, ICH Guidelines.

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
ANALYTICAL METHOD AND VALIDATION FOR DETERMINATION OF ELINZANETANT IN BULK FORM AND MARKETED PHARMACEUTICAL DOSAGE FORM BY USING RP-HPLC — Narra Kavitha*, Gunnakolu Anusha, V. Anuja Kumari, Erla Arun, Nakka Balakrishna, Kavali Bhanu Prakash · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS