Indoor Air Quality and Environmental Safety in Neonatal Intensive Care Unit in Al-Najaf, Iraq: A Cross Sectional Study of Incubators and Surrounding Air

Objective: To measure selected indoor air quality parameters within neonatal incubators and neonatal intensive care unit rooms using a calibrated digital monitoring device Study Design: Descriptive analytical cross-sectional studyPlace and Duration of Study: This study was conducted at the neonatal intensive care unit of Al-Zahraa Teaching Hospital in Al-Najaf, Iraq, from 1st October 2024 to 31st March 2025. Methodology: The study included 12 active neonatal Incubators and two neonatal intensive care unit rooms. Air quality parameters including temperature, relative humidity, particulate matter (PM1.0, PM2.5 and PM10), carbon dioxide, formaldehyde, and total volatile organic compounds, were measured using a portable monitoring device. Measurements were conducted during peak working hours at different locations within the rooms and incubators. Results: The research results demonstrated that the majority of air quality indicators met international standards for acceptable levels. The temperature and carbon dioxide levels met the recommended values, but relative humidity fell below the recommended threshold. The PM2.5 and PM10 levels remained within acceptable range while formaldehyde and total volatile organic compounds gaseous pollutants appeared at extremely low levels. The two rooms showed no significant statistical differences between them (P>0.05). Conclusion: The neonatal intensive care unit indoor air quality assessment showed acceptable results although the facility needed humidity level improvements. The establishment needs continuous air quality assessment together with control systems to maintain protection for neonates

Authors

Institutions

Publication Details

Journal
Medical Forum Monthly
Published
2026-11-01
DOI
https://doi.org/10.60110/medforum.37.10.22
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Indoor Air Quality and Environmental Safety in Neonatal Intensive Care Unit in Al-Najaf, Iraq: A Cross Sectional Study of Incubators and Surrounding Air

Fulath Abdul-Redah Muhsin, Zainab Hassan Ghazai
3 links
Medical Forum Monthly
Indoor Air Quality and Microbial Exposure
article

Indoor Air Quality and Environmental Safety in Neonatal Intensive Care Unit in Al-Najaf, Iraq: A Cross Sectional Study of Incubators and Surrounding Air

Fulath Abdul-Redah Muhsin, Zainab Hassan Ghazai
article en

Abstract

Objective: To measure selected indoor air quality parameters within neonatal incubators and neonatal intensive care unit rooms using a calibrated digital monitoring device Study Design: Descriptive analytical cross-sectional studyPlace and Duration of Study: This study was conducted at the neonatal intensive care unit of Al-Zahraa Teaching Hospital in Al-Najaf, Iraq, from 1st October 2024 to 31st March 2025. Methodology: The study included 12 active neonatal Incubators and two neonatal intensive care unit rooms. Air quality parameters including temperature, relative humidity, particulate matter (PM1.0, PM2.5 and PM10), carbon dioxide, formaldehyde, and total volatile organic compounds, were measured using a portable monitoring device. Measurements were conducted during peak working hours at different locations within the rooms and incubators. Results: The research results demonstrated that the majority of air quality indicators met international standards for acceptable levels. The temperature and carbon dioxide levels met the recommended values, but relative humidity fell below the recommended threshold. The PM2.5 and PM10 levels remained within acceptable range while formaldehyde and total volatile organic compounds gaseous pollutants appeared at extremely low levels. The two rooms showed no significant statistical differences between them (P>0.05). Conclusion: The neonatal intensive care unit indoor air quality assessment showed acceptable results although the facility needed humidity level improvements. The establishment needs continuous air quality assessment together with control systems to maintain protection for neonates

Medical Forum MonthlyVol. 37(10)
Al-Furat Al-Awsat Technical University (IQ)
Good health and well-being
Openalex Percentile: Top 18%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon