B-shaped Interferometric Fiber Structure: A Powerful Dual-Channel Sensing Device for Detecting Fructose and Glucose in Pure Honey

We report a B-shaped Mach-Zehnder interferometer (MZI)-based fiber sensor for monitoring honey quality. The MZI was fabricated using a single-mode fiber (SMF) wrapped in a B-shaped configuration with two loops, each functioning as a separate MZI. One MZI detects fructose, and the other detects glucose. The adulterated samples were prepared by adding fructose and glucose to pure honey, with concentrations ranging from 0% to 50%. For fructose detection, the sensitivity was −0.236 nm/%. For glucose detection, the sensitivity was −0.14514 nm/%. The results show that the B-shaped MZI can function as a dual-parameter sensor for monitoring honey quality.

Authors

Institutions

Publication Details

Journal
Fiber & Integrated Optics
Published
2026-11-01
DOI
https://doi.org/10.1080/01468030.2026.2752351
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

B-shaped Interferometric Fiber Structure: A Powerful Dual-Channel Sensing Device for Detecting Fructose and Glucose in Pure Honey

Sarah Kadhim Al-Hayali, Zahraa Qasim Mohammed
3 links
Fiber & Integrated Optics
Advanced Fiber Optic Sensors
article

B-shaped Interferometric Fiber Structure: A Powerful Dual-Channel Sensing Device for Detecting Fructose and Glucose in Pure Honey

Sarah Kadhim Al-Hayali, Zahraa Qasim Mohammed
article en

Abstract

We report a B-shaped Mach-Zehnder interferometer (MZI)-based fiber sensor for monitoring honey quality. The MZI was fabricated using a single-mode fiber (SMF) wrapped in a B-shaped configuration with two loops, each functioning as a separate MZI. One MZI detects fructose, and the other detects glucose. The adulterated samples were prepared by adding fructose and glucose to pure honey, with concentrations ranging from 0% to 50%. For fructose detection, the sensitivity was −0.236 nm/%. For glucose detection, the sensitivity was −0.14514 nm/%. The results show that the B-shaped MZI can function as a dual-parameter sensor for monitoring honey quality.

Fiber & Integrated Optics
University of Baghdad (IQ), Al-Turath University (IQ)
Openalex Percentile: Top 24%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon