IFT–Wettability Interplay and Force-Regime Transition in Chemical EOR: A Mechanistic SI/FI Diagnostic Approach

Despite the crucial role of enhanced oil recovery (EOR) in meeting rising energy demands, interpretation of chemical EOR (CEOR) performance is limited by reliance on interfacial tension (IFT) and contact angle (CA) data. Most studies correlate IFT and CA with core flooding results, masking the contribution of capillary and gravity forces. The study introduces a force-isolation workflow that distinguishes capillary-, viscous-, and gravity-governed recovery by combining spontaneous imbibition (SI) and forced imbibition (FI) experiments conducted on clay-rich Bandera Gray sandstone cores. The key novelty is a modified Amott cell that applies controlled hydraulic pressure heads (10–30 cm) during the FI experiment, which allows measuring the lowest pressure to trigger oil displacement in every fluid system. Four injection systems—high-salinity (HS) brine, low-salinity (LS) brine, an anionic surfactant (sodium lauryl sulfate, SLS), and a cationic surfactant (cetyltrimethylammonium bromide, CTAB)—are selected to induce interfacial conditions. SLS generates high capillary pressure and a near-zero contact angle, promoting capillary-assisted viscous FI at the lowest pressure threshold, achieving 41% SI recovery and an SI/FI ratio of ~80%. By contrast, CTAB produces a low IFT but insufficient capillary pressure, resulting in gravity-driven SI with 5% recovery and viscous-dominated FI, with an SI/FI ratio of ~9%. The brine systems exhibit viscous-assisted capillary recovery, requiring the highest entry pressure. The SI/FI ratio classifies the force regimes, confirming that capillary support governs mobility control under SI and FI conditions. This force-regime approach provides a more reliable basis for CEOR formulation design than IFT and CA screening alone.

Authors

Institutions

Publication Details

Journal
Journal of Engineering
Published
2026-11-01
DOI
https://doi.org/10.31026/j.eng.2026.11.02
Primary Topic
Enhanced Oil Recovery Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IFT–Wettability Interplay and Force-Regime Transition in Chemical EOR: A Mechanistic SI/FI Diagnostic Approach

Ahmad Sari, Lionel Esteban, Nurudeen Peter Yekeen, Faaiz Al-Shajalee et al.
1 links
Journal of Engineering
Enhanced Oil Recovery Techniques
article

IFT–Wettability Interplay and Force-Regime Transition in Chemical EOR: A Mechanistic SI/FI Diagnostic Approach

Ahmad Sari, Lionel Esteban, Nurudeen Peter Yekeen, Faaiz Al-Shajalee, Haider A. Falih Al-Tarim, Hussein H. Hussein
article en

Abstract

Despite the crucial role of enhanced oil recovery (EOR) in meeting rising energy demands, interpretation of chemical EOR (CEOR) performance is limited by reliance on interfacial tension (IFT) and contact angle (CA) data. Most studies correlate IFT and CA with core flooding results, masking the contribution of capillary and gravity forces. The study introduces a force-isolation workflow that distinguishes capillary-, viscous-, and gravity-governed recovery by combining spontaneous imbibition (SI) and forced imbibition (FI) experiments conducted on clay-rich Bandera Gray sandstone cores. The key novelty is a modified Amott cell that applies controlled hydraulic pressure heads (10–30 cm) during the FI experiment, which allows measuring the lowest pressure to trigger oil displacement in every fluid system. Four injection systems—high-salinity (HS) brine, low-salinity (LS) brine, an anionic surfactant (sodium lauryl sulfate, SLS), and a cationic surfactant (cetyltrimethylammonium bromide, CTAB)—are selected to induce interfacial conditions. SLS generates high capillary pressure and a near-zero contact angle, promoting capillary-assisted viscous FI at the lowest pressure threshold, achieving 41% SI recovery and an SI/FI ratio of ~80%. By contrast, CTAB produces a low IFT but insufficient capillary pressure, resulting in gravity-driven SI with 5% recovery and viscous-dominated FI, with an SI/FI ratio of ~9%. The brine systems exhibit viscous-assisted capillary recovery, requiring the highest entry pressure. The SI/FI ratio classifies the force regimes, confirming that capillary support governs mobility control under SI and FI conditions. This force-regime approach provides a more reliable basis for CEOR formulation design than IFT and CA screening alone.

Journal of EngineeringVol. 32(11)
University of Kirkuk (IQ), Edith Cowan University (AU), Commonwealth Scientific and Industrial Research Organisation (AU), University of Baghdad (IQ), Ministry of Oil (KW)
Openalex Percentile: Top 19%
Enhanced Oil Recovery Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon