Low-voltage, ultra-broadband wearable MEMS ultrasound: a frequency-merged, wafer-scale framework for continuous in vivo cardiovascular imaging and monitoring

Continuous, non-invasive monitoring of central hemodynamics is essential for advanced cardiovascular care. Although wearable ultrasound enables deep-tissue sensing, its widespread clinical adoption is limited by the inherent physical trade-off between driving voltage and acoustic bandwidth, alongside the challenges of scaling microelectronic ultrasound devices for medical imaging. Here, we report a wearable, 81.7% broadband piezoelectric micromachined ultrasonic transducer (pMUT) array driven at a low voltage of 5 Vp. To address these bottlenecks, this study introduces two parallel innovations. First, we introduce a novel frequency-merging design, quantified by an equivalent circuit model, to effectively decouple the voltage-bandwidth trade-off. Second, we provide a comprehensive framework directing a scalable silicon-on-insulator wafer-level fabrication process towards fully in vitro and in vivo experimental characterizations for medical imaging. Enabled by these advancements, in vitro characterization demonstrates 0.64 mm axial and 1.27 mm lateral resolutions while maintaining a penetration depth of up to 9 cm in wire phantoms. In vivo, the wearable patch achieves comparable high-fidelity B-mode and M-mode imaging of carotid, brachial, and radial arteries within 4 cm depth to commercial rigid probes. Crucially, the device enables continuous, stable hemodynamic monitoring under limited daily postural activities for up to 9 hours. Inter-subject validation confirms precise blood pressure measurements, with deviations of 2.2 mmHg compared to FDA-approved clinical monitors. Leveraging standard semiconductor batch manufacturing, this work addresses the technical mismatch between low-voltage wearable devices and high-performance ultrasound transduction, creating a feasible development path for highly integrated, mass-producible cardiovascular ultrasound systems-on-chip.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2026-11-02
DOI
https://doi.org/10.1038/s41378-026-01451-6
Primary Topic
Advanced MEMS and NEMS Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-voltage, ultra-broadband wearable MEMS ultrasound: a frequency-merged, wafer-scale framework for continuous in vivo cardiovascular imaging and monitoring

Hang Gao, Boyuan Wei, Chengjun Huang, Zijie Zhao et al.
Microsystems & Nanoengineering
Advanced MEMS and NEMS Technologies
article

Low-voltage, ultra-broadband wearable MEMS ultrasound: a frequency-merged, wafer-scale framework for continuous in vivo cardiovascular imaging and monitoring

Hang Gao, Boyuan Wei, Chengjun Huang, Zijie Zhao, Yang Jin, Chenfang Yan, Jiahan Yu, 乔奕, Tong Jin, Yucheng Lin, Jianwen Luo, Rui Wang, Lingqian Zhang, Hongyang Chen, Qiong He
article en

Abstract

Continuous, non-invasive monitoring of central hemodynamics is essential for advanced cardiovascular care. Although wearable ultrasound enables deep-tissue sensing, its widespread clinical adoption is limited by the inherent physical trade-off between driving voltage and acoustic bandwidth, alongside the challenges of scaling microelectronic ultrasound devices for medical imaging. Here, we report a wearable, 81.7% broadband piezoelectric micromachined ultrasonic transducer (pMUT) array driven at a low voltage of 5 Vp. To address these bottlenecks, this study introduces two parallel innovations. First, we introduce a novel frequency-merging design, quantified by an equivalent circuit model, to effectively decouple the voltage-bandwidth trade-off. Second, we provide a comprehensive framework directing a scalable silicon-on-insulator wafer-level fabrication process towards fully in vitro and in vivo experimental characterizations for medical imaging. Enabled by these advancements, in vitro characterization demonstrates 0.64 mm axial and 1.27 mm lateral resolutions while maintaining a penetration depth of up to 9 cm in wire phantoms. In vivo, the wearable patch achieves comparable high-fidelity B-mode and M-mode imaging of carotid, brachial, and radial arteries within 4 cm depth to commercial rigid probes. Crucially, the device enables continuous, stable hemodynamic monitoring under limited daily postural activities for up to 9 hours. Inter-subject validation confirms precise blood pressure measurements, with deviations of 2.2 mmHg compared to FDA-approved clinical monitors. Leveraging standard semiconductor batch manufacturing, this work addresses the technical mismatch between low-voltage wearable devices and high-performance ultrasound transduction, creating a feasible development path for highly integrated, mass-producible cardiovascular ultrasound systems-on-chip.

Microsystems & NanoengineeringVol. 12(1)
Chinese Academy of Sciences (CN), Chinese PLA General Hospital (CN), Institute of Microelectronics (CN), University of Chinese Academy of Sciences (CN), Tsinghua University (CN)
National Key Research and Development Program of China
Good health and well-being
Openalex Percentile: Top 26%
Advanced MEMS and NEMS Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon