Composite energy geo-structures for building decarbonization

Energy geo-structures (EGs) integrate heat-exchange loops into geotechnical structures to provide heating and cooling using shallow geothermal energy. However, the contribution of standalone EGs to building thermal demand may decrease in large-scale applications and can be accompanied by seasonal ground thermal imbalance. To overcome the limitations of standalone EGs, a composite EG system integrating energy tunnels (ET), energy diaphragm walls (EDW), energy piles (EP), and boreholes (BHE) is proposed. A three-dimensional numerical model of a composite energy geo-structure system was established and evaluated against experimental or published benchmark data for the component subsystems. The model was used to investigate the short- and long-term thermal performance of the composite system. The results show that, despite localized reductions in the heat flux in length of EP and BHE, the composite EGs achieved a higher total heat exchange capacity—1.90, 2.70, 11.24, and 24.87 times greater than those of standalone ET, EDW, EP groups, and BHE arrays, respectively. Over the ten-year simulation, ET and EDW showed limited interannual variation, while the EP-BHE subsystem approached a repeatable seasonal response after the first complete annual cycle. Additionally, under the prescribed building-load conditions, circulating flow rate and soil thermal conductivity mainly altered the local ground-temperature field, whereas annual heat exchange was primarily determined by the imposed building demand and the COP-dependent ground-side load. Compared with coal-fired heating and electric air-conditioning under the same building load, the composite system reduced annual operational emissions by 49.80% (962.03 t CO 2 -eq), demonstrating its potential for efficient and low-carbon building thermal supply.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-11-01
DOI
https://doi.org/10.1016/j.csite.2026.108690
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Composite energy geo-structures for building decarbonization

Tian You, Chanjuan Han, Hongzhi Cui, Lijie Zhu
1 links
Case Studies in Thermal Engineering
Geothermal Energy Systems and Applications
article

Composite energy geo-structures for building decarbonization

Tian You, Chanjuan Han, Hongzhi Cui, Lijie Zhu
article en

Abstract

Energy geo-structures (EGs) integrate heat-exchange loops into geotechnical structures to provide heating and cooling using shallow geothermal energy. However, the contribution of standalone EGs to building thermal demand may decrease in large-scale applications and can be accompanied by seasonal ground thermal imbalance. To overcome the limitations of standalone EGs, a composite EG system integrating energy tunnels (ET), energy diaphragm walls (EDW), energy piles (EP), and boreholes (BHE) is proposed. A three-dimensional numerical model of a composite energy geo-structure system was established and evaluated against experimental or published benchmark data for the component subsystems. The model was used to investigate the short- and long-term thermal performance of the composite system. The results show that, despite localized reductions in the heat flux in length of EP and BHE, the composite EGs achieved a higher total heat exchange capacity—1.90, 2.70, 11.24, and 24.87 times greater than those of standalone ET, EDW, EP groups, and BHE arrays, respectively. Over the ten-year simulation, ET and EDW showed limited interannual variation, while the EP-BHE subsystem approached a repeatable seasonal response after the first complete annual cycle. Additionally, under the prescribed building-load conditions, circulating flow rate and soil thermal conductivity mainly altered the local ground-temperature field, whereas annual heat exchange was primarily determined by the imposed building demand and the COP-dependent ground-side load. Compared with coal-fired heating and electric air-conditioning under the same building load, the composite system reduced annual operational emissions by 49.80% (962.03 t CO 2 -eq), demonstrating its potential for efficient and low-carbon building thermal supply.

Case Studies in Thermal EngineeringVol. 88
Shenzhen University (CN), Shanghai Jiao Tong University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Guangdong Province
Climate action, Affordable and clean energy, Industry, innovation and infrastructure, Sustainable cities and communities
Openalex Percentile: Top 35%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon