Comparative Accuracy of Lower Limb Osteometry from CT Scans Versus Direct Bone Measurements

Abstract Radiographic imaging is increasingly used for osteometric data collection in clinical and forensic settings, although measurement accuracy may be affected by imaging protocols and scanning parameters. This study evaluated the agreement between CT-derived lower-limb skeletal measurements and direct dry-bone measurements. Maximum (MLF) and bicondylar (BLF) femoral lengths and maximum (LMT) and malleolar-trochlear (MTL) tibial lengths were recorded from 68 femora and 49 tibiae from anatomical collections using an osteometric board, and through CT images of the same bones. Agreement was assessed using paired comparisons, absolute-agreement intraclass correlation coefficients (ICCs), Bland–Altman analysis, technical error of measurement (TEM), and relative TEM (rTEM). There were statistically significant differences between CT-derived measurements and direct measurements for MLF, BLF, LMT, and MTL; however, mean biases were small, ranging from − 0.46 to 0.76 mm. No significant proportional bias was detected. Intra-observer rTEM ranged from 0.10% to 0.41%, with ICCs of 0.9936–0.9993, while inter-observer rTEM ranged from 0.11% to 0.23%, with ICCs of 0.9975–0.9992. CT-derived femoral and tibial measurements demonstrated excellent agreement with direct dry-bone osteometry. Although small statistically significant method differences were present, their magnitude was unlikely to be practically meaningful. In summary, measuring from CT images provided precise, repeatable, and reproducible dry skeletal measurements and represents a reliable non-invasive alternative for tibia and femora at autopsy, when direct skeletal measurement is unavailable or impractical.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-01
DOI
https://doi.org/10.21203/rs.3.rs-11250517/v1
Primary Topic
Forensic Anthropology and Bioarchaeology Studies
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Comparative Accuracy of Lower Limb Osteometry from CT Scans Versus Direct Bone Measurements

Peter Zioupos, Nicholas Márquez‐Grant, Tooba Siddiqui, Elisa Baldini et al.
Research Square
Forensic Anthropology and Bioarchaeology Studies
preprint

Comparative Accuracy of Lower Limb Osteometry from CT Scans Versus Direct Bone Measurements

Peter Zioupos, Nicholas Márquez‐Grant, Tooba Siddiqui, Elisa Baldini, Claire Carter, Mark Viner, Keiran Kelly
preprint en

Abstract

Abstract Radiographic imaging is increasingly used for osteometric data collection in clinical and forensic settings, although measurement accuracy may be affected by imaging protocols and scanning parameters. This study evaluated the agreement between CT-derived lower-limb skeletal measurements and direct dry-bone measurements. Maximum (MLF) and bicondylar (BLF) femoral lengths and maximum (LMT) and malleolar-trochlear (MTL) tibial lengths were recorded from 68 femora and 49 tibiae from anatomical collections using an osteometric board, and through CT images of the same bones. Agreement was assessed using paired comparisons, absolute-agreement intraclass correlation coefficients (ICCs), Bland–Altman analysis, technical error of measurement (TEM), and relative TEM (rTEM). There were statistically significant differences between CT-derived measurements and direct measurements for MLF, BLF, LMT, and MTL; however, mean biases were small, ranging from − 0.46 to 0.76 mm. No significant proportional bias was detected. Intra-observer rTEM ranged from 0.10% to 0.41%, with ICCs of 0.9936–0.9993, while inter-observer rTEM ranged from 0.11% to 0.23%, with ICCs of 0.9975–0.9992. CT-derived femoral and tibial measurements demonstrated excellent agreement with direct dry-bone osteometry. Although small statistically significant method differences were present, their magnitude was unlikely to be practically meaningful. In summary, measuring from CT images provided precise, repeatable, and reproducible dry skeletal measurements and represents a reliable non-invasive alternative for tibia and femora at autopsy, when direct skeletal measurement is unavailable or impractical.

Research Square
University of Hull (GB), University of Oxford (GB), Cranfield University (GB), Defence Academy of the United Kingdom (GB)
Cranfield University
Good health and well-being
Forensic Anthropology and Bioarchaeology Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon