Seismic performance optimization analysis of HPEC beam to H-section column joints

To fully exploit the advantages of steel-concrete composite structures and reduce material consumption and self-weight, this study proposes a novel prefabricated hollow-core partially encased composite beam (HPEC)-to-H-section column joint (PHHJ); however, its seismic performance and key detailing effects remain insufficiently understood. Six 1/2-scale specimens were tested under low-cycle reversed loading to evaluate the effects of hollow ratio, stiffener length, and cover plate length on failure mode, hysteretic behavior, energy dissipation, and ductility. Refined ABAQUS models were validated and used for parametric analyses of stiffener position, widened flange, and connection form. The primary failure modes were flexural failure and connection failure. The hysteretic curves exhibited a shuttle shape with good energy dissipation, and the maximum equivalent viscous damping coefficient reached 0.24. Initial stiffness degradation was mainly caused by buckling of the H-section steel beam flange, whereas later degradation was governed by steel yielding and concrete crushing. The maximum ductility coefficient was 1.61. Bearing capacity was relatively insensitive to stiffener length, cover plate length, and hollow ratio, and its degradation mainly depended on damage to reinforced concrete in the filling area. FEM results show that stiffeners relocate the plastic hinge away from the column face, while a widened flange alleviates stress concentration at the interface between the HPEC flange edge and the beam end plate. A connection combining stiffeners and a widened flange is recommended, with stiffener length > 200 mm, widened flange width matching the column flange width, and length ≥ 200 mm. These findings provide a reference for the seismic design and engineering application of HPEC beam-column joints.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-10-31
DOI
https://doi.org/10.1038/s41598-026-77371-2
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic performance optimization analysis of HPEC beam to H-section column joints

Yifan Yao, Shanzheng Sun, Wei Wang, Jing Dong et al.
Scientific Reports
Structural Load-Bearing Analysis
article

Seismic performance optimization analysis of HPEC beam to H-section column joints

Yifan Yao, Shanzheng Sun, Wei Wang, Jing Dong, Yuan Liu
article en

Abstract

To fully exploit the advantages of steel-concrete composite structures and reduce material consumption and self-weight, this study proposes a novel prefabricated hollow-core partially encased composite beam (HPEC)-to-H-section column joint (PHHJ); however, its seismic performance and key detailing effects remain insufficiently understood. Six 1/2-scale specimens were tested under low-cycle reversed loading to evaluate the effects of hollow ratio, stiffener length, and cover plate length on failure mode, hysteretic behavior, energy dissipation, and ductility. Refined ABAQUS models were validated and used for parametric analyses of stiffener position, widened flange, and connection form. The primary failure modes were flexural failure and connection failure. The hysteretic curves exhibited a shuttle shape with good energy dissipation, and the maximum equivalent viscous damping coefficient reached 0.24. Initial stiffness degradation was mainly caused by buckling of the H-section steel beam flange, whereas later degradation was governed by steel yielding and concrete crushing. The maximum ductility coefficient was 1.61. Bearing capacity was relatively insensitive to stiffener length, cover plate length, and hollow ratio, and its degradation mainly depended on damage to reinforced concrete in the filling area. FEM results show that stiffeners relocate the plastic hinge away from the column face, while a widened flange alleviates stress concentration at the interface between the HPEC flange edge and the beam end plate. A connection combining stiffeners and a widened flange is recommended, with stiffener length > 200 mm, widened flange width matching the column flange width, and length ≥ 200 mm. These findings provide a reference for the seismic design and engineering application of HPEC beam-column joints.

Scientific Reports
PLA Rocket Force University of Engineering (CN)
Openalex Percentile: Top 18%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.