Comparative Culture-Based Evaluation of Dental Unit Waterline Biofilm Contamination

Background: DUWLs easily become colonized by microorganisms due to narrow tubing, intermittent flow, and stagnation allowing adhesion and biofilm formation to occur. Patients and dental health-care workers are potentially at risk of exposure to microorganisms during procedures if contaminated outlet water is present. Objectives: The aim of this study was to assess the microbial contamination, biofilm formation and waterline hygiene-related parameters in governmental and private dental clinics. Methods: This study was comparative cross sectional laboratory study carried out at Al-Hilla Surgical Teaching Hospital and clinics from 2/1/2026 to 30/5/2026. 60 dental units were involved in the study (30 governmental and 30 private dental units). Two hundred and forty (240) water samples were taken from air-water syringes, high-speed handpiece lines, cup fillers and source water/reservoir bottles. The culture-based heterotrophic plate counts were done and reported as CFUs/mL. Conventional microbiological and biochemical tests were used for the identification of isolates and selected bacteria were evaluated for the ability to form biofilms using the microtiter plate method. Results: The median heterotrophic counts were higher in governmental clinic than in the private clinic (1200 vs. 430 CFU/mL, p<0.001). The overall prevalence rate was 54.2% with more in governmental than in private clinics (70.0% vs. 38.3%, p<0.001). Lines using high speed handpieces were the most contaminated. Flushing decreased the median counts from 920 to 380CFU/mL with 35.0% still being unacceptable (p<0.001). Of the isolates tested, 55.0% had moderate or strong biofilm production and there was a positive correlation with CFU/mL (rho=0.58, p<0.001). The independent risk factors were lack of disinfection, lack of filtration, lack of flushing and the age of the unit (> 5 years). Conclusion: DUWL contamination was common, biofilm related, and associated with inadequate maintenance practice, therefore regular disinfection, filtration, flushing and microbiological monitoring practices were recommended.

Authors

Institutions

Publication Details

Journal
IPS Journal of Applied Microbiology and Biotechnology
Published
2026-10-31
DOI
https://doi.org/10.54117/ijamb.v6i4.186
Primary Topic
Infection Control in Healthcare
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Culture-Based Evaluation of Dental Unit Waterline Biofilm Contamination

Lara Hashem Abdzaid
IPS Journal of Applied Microbiology and Biotechnology
Infection Control in Healthcare
article

Comparative Culture-Based Evaluation of Dental Unit Waterline Biofilm Contamination

Lara Hashem Abdzaid
article en

Abstract

Background: DUWLs easily become colonized by microorganisms due to narrow tubing, intermittent flow, and stagnation allowing adhesion and biofilm formation to occur. Patients and dental health-care workers are potentially at risk of exposure to microorganisms during procedures if contaminated outlet water is present. Objectives: The aim of this study was to assess the microbial contamination, biofilm formation and waterline hygiene-related parameters in governmental and private dental clinics. Methods: This study was comparative cross sectional laboratory study carried out at Al-Hilla Surgical Teaching Hospital and clinics from 2/1/2026 to 30/5/2026. 60 dental units were involved in the study (30 governmental and 30 private dental units). Two hundred and forty (240) water samples were taken from air-water syringes, high-speed handpiece lines, cup fillers and source water/reservoir bottles. The culture-based heterotrophic plate counts were done and reported as CFUs/mL. Conventional microbiological and biochemical tests were used for the identification of isolates and selected bacteria were evaluated for the ability to form biofilms using the microtiter plate method. Results: The median heterotrophic counts were higher in governmental clinic than in the private clinic (1200 vs. 430 CFU/mL, p<0.001). The overall prevalence rate was 54.2% with more in governmental than in private clinics (70.0% vs. 38.3%, p<0.001). Lines using high speed handpieces were the most contaminated. Flushing decreased the median counts from 920 to 380CFU/mL with 35.0% still being unacceptable (p<0.001). Of the isolates tested, 55.0% had moderate or strong biofilm production and there was a positive correlation with CFU/mL (rho=0.58, p<0.001). The independent risk factors were lack of disinfection, lack of filtration, lack of flushing and the age of the unit (> 5 years). Conclusion: DUWL contamination was common, biofilm related, and associated with inadequate maintenance practice, therefore regular disinfection, filtration, flushing and microbiological monitoring practices were recommended.

IPS Journal of Applied Microbiology and BiotechnologyVol. 6(4)
University of Babylon (IQ)
Openalex Percentile: Top 11%
Infection Control in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Comparative Culture-Based Evaluation of Dental Unit Waterline Biofilm Contamination — Lara Hashem Abdzaid · IPS Journal of Applied Microbiology and Biotechnology (2026) | TGRS Research Map | TGRS