Lean energy assessment for wineries: A data-driven framework for screening potentially avoidable electricity demand

Improving sustainability in process-intensive industries requires moving beyond annual totals to determine when, where and why avoidable electricity demand arises. This study develops the Lean Energy Assessment for Wineries (LEAW), a data-driven framework that translates traditional Lean muda into eight Energy Muda and connects meter-derived signals with operational verification. An exploratory application combined 8,760 hourly observations from an industrial winery in 2022 with process mapping and structured Gemba-walk sessions. Plant electricity use was 3.83 GWh. Bottling and warehousing represented the largest share of plant electricity use (31.2 %), followed by refrigeration, with measured fixed refrigeration accounting for 12.9 % and baseline subtraction from the non-disaggregated balance estimating an additional 13.2 % attributable to seasonal rented units, for a total refrigeration-associated share of 26.1 %. Pumping accounted for a further 9.7 %. The August–October harvest represented 40.8 % of demand, while crushing, press compressors and pumping showed Harvest Energy Shares of 95.7 %, 64.4 % and 50.8 %. Night, weekend and harvest indicators differentiated seasonal loads from persistent services and generated hypotheses of potential Energy Muda. Operational investigation documented insulation deficiencies, long-distance hot-water delivery, candidate over-conservative temperature practices, monitoring gaps and limited formalization of energy-related knowledge. A participatory Action Priority Score identified refrigerant-piping insulation as the leading follow-up action. However, 21.5 % of plant demand was not covered by complete dedicated-meter series and the proposed actions were not implemented or evaluated ex post. This single-case application therefore demonstrates the diagnostic feasibility of LEAW rather than verified energy savings; its effectiveness and transferability require validation through implementation and additional cases.

Authors

Institutions

Publication Details

Journal
Sustainable Energy Technologies and Assessments
Published
2026-10-31
DOI
https://doi.org/10.1016/j.seta.2026.105556
Primary Topic
Energy Efficiency and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lean energy assessment for wineries: A data-driven framework for screening potentially avoidable electricity demand

Rino Gubiani, Gellio Ciotti, Alessandro Zironi, Pietro Romano et al.
Sustainable Energy Technologies and Assessments
Energy Efficiency and Management
article

Lean energy assessment for wineries: A data-driven framework for screening potentially avoidable electricity demand

Rino Gubiani, Gellio Ciotti, Alessandro Zironi, Pietro Romano, R. Zironi
article en

Abstract

Improving sustainability in process-intensive industries requires moving beyond annual totals to determine when, where and why avoidable electricity demand arises. This study develops the Lean Energy Assessment for Wineries (LEAW), a data-driven framework that translates traditional Lean muda into eight Energy Muda and connects meter-derived signals with operational verification. An exploratory application combined 8,760 hourly observations from an industrial winery in 2022 with process mapping and structured Gemba-walk sessions. Plant electricity use was 3.83 GWh. Bottling and warehousing represented the largest share of plant electricity use (31.2 %), followed by refrigeration, with measured fixed refrigeration accounting for 12.9 % and baseline subtraction from the non-disaggregated balance estimating an additional 13.2 % attributable to seasonal rented units, for a total refrigeration-associated share of 26.1 %. Pumping accounted for a further 9.7 %. The August–October harvest represented 40.8 % of demand, while crushing, press compressors and pumping showed Harvest Energy Shares of 95.7 %, 64.4 % and 50.8 %. Night, weekend and harvest indicators differentiated seasonal loads from persistent services and generated hypotheses of potential Energy Muda. Operational investigation documented insulation deficiencies, long-distance hot-water delivery, candidate over-conservative temperature practices, monitoring gaps and limited formalization of energy-related knowledge. A participatory Action Priority Score identified refrigerant-piping insulation as the leading follow-up action. However, 21.5 % of plant demand was not covered by complete dedicated-meter series and the proposed actions were not implemented or evaluated ex post. This single-case application therefore demonstrates the diagnostic feasibility of LEAW rather than verified energy savings; its effectiveness and transferability require validation through implementation and additional cases.

Sustainable Energy Technologies and AssessmentsVol. 95
University of Udine (IT)
Openalex Percentile: Top 35%
Energy Efficiency and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon