What Determines the Charge State Distribution of Proteins Electrosprayed from Non-Denaturing Solutions?

Abstract The maximum charge on globular electrosprayed protein ions has been rationalized as the maximal charge sustainable by a solvent drop of comparable size, in turn determined by either small ion evaporation or Rayleigh’s limiting charge. Here we show that spontaneous ion evaporation may continue after the protein ion has dried. Multiply charged cations C+z of bovine serum albumin (BSA) or ovalbumin are electrosprayed into dry ambient air from aqueous solutions of ammonium acetate or thriethylammonium formate. A unique dry protein charge state z is isolated (<1 ms) in a first mobility instrument and passed through a parabolic flow tubular reactor (∼200 ms) where dry ion evaporation transitions C+z → C+z−1 → C+z−2... take place. The protein charge state distribution exiting the reactor is then determined (<1 ms) in a second mobility device. All naturally charged BSA+z and ovalbumin+z ions undergo substantial room temperature charge loss within the reactor, both in ammonium acetate and in triethylammonium formate buffers. The observed maximal charge and the charge distribution are therefore determined by the kinetics of dry ion evaporation from the surface of the dry protein, and depend on the residence time, the temperature and the nature of the evaporating ion. The often-observed low charge states characteristic of buffers containing certain amines is due to the weaker binding of these protonated amines to the protein compared to H+ or NH4+. Maximal charge states may hence be obtained from cold sources with short residence times and selected buffers. The dry ion evaporation here observed may not apply to very large proteins.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-10-31
DOI
https://doi.org/10.1021/acs.analchem.6c03295
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

What Determines the Charge State Distribution of Proteins Electrosprayed from Non-Denaturing Solutions?

Luis J. Perez-Lorenzo, Michel B. Attoui, Juan Fernández de la Mora
Analytical Chemistry
Mass Spectrometry Techniques and Applications
article

What Determines the Charge State Distribution of Proteins Electrosprayed from Non-Denaturing Solutions?

Luis J. Perez-Lorenzo, Michel B. Attoui, Juan Fernández de la Mora
article en

Abstract

Abstract The maximum charge on globular electrosprayed protein ions has been rationalized as the maximal charge sustainable by a solvent drop of comparable size, in turn determined by either small ion evaporation or Rayleigh’s limiting charge. Here we show that spontaneous ion evaporation may continue after the protein ion has dried. Multiply charged cations C+z of bovine serum albumin (BSA) or ovalbumin are electrosprayed into dry ambient air from aqueous solutions of ammonium acetate or thriethylammonium formate. A unique dry protein charge state z is isolated (<1 ms) in a first mobility instrument and passed through a parabolic flow tubular reactor (∼200 ms) where dry ion evaporation transitions C+z → C+z−1 → C+z−2... take place. The protein charge state distribution exiting the reactor is then determined (<1 ms) in a second mobility device. All naturally charged BSA+z and ovalbumin+z ions undergo substantial room temperature charge loss within the reactor, both in ammonium acetate and in triethylammonium formate buffers. The observed maximal charge and the charge distribution are therefore determined by the kinetics of dry ion evaporation from the surface of the dry protein, and depend on the residence time, the temperature and the nature of the evaporating ion. The often-observed low charge states characteristic of buffers containing certain amines is due to the weaker binding of these protonated amines to the protein compared to H+ or NH4+. Maximal charge states may hence be obtained from cold sources with short residence times and selected buffers. The dry ion evaporation here observed may not apply to very large proteins.

Analytical Chemistry
Centre National de la Recherche Scientifique (FR), Université Paris-Est Créteil (FR), Université Paris Cité (FR), Yale University (US), Laboratoire Interuniversitaire des Systèmes Atmosphériques (FR)
Openalex Percentile: Top 27%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon