Cost‐effectiveness analysis comparing advanced hybrid closed‐loop automated insulin delivery with multiple daily insulin injections and continuous glucose monitoring in adults with type 1 diabetes in Japan

AIM: The use of automated insulin delivery systems, including the MiniMed™ 780G advanced hybrid closed-loop system, has been shown to improve glycemic management in people with type 1 diabetes (T1D). The aim was to assess the cost-effectiveness of the MiniMed 780G system versus multiple daily injections (MDI) of insulin in combination with continuous glucose monitoring (CGM) in the management of people with T1D with elevated HbA1c levels in Japan. METHODS: Modeling was performed using the IQVIA Core Diabetes Model and clinical input data were sourced from a randomized controlled trial. A time horizon of 55 years, a discount rate of 2.0% per annum, and a payer perspective were used. Sensitivity analyses were used to examine the robustness of base-case results. RESULTS: In the base-case, an incremental cost-effectiveness ratio (ICER) of JPY 4,723,991 per quality-adjusted life year (QALY) gained was found, with an incremental benefit of 2.83 quality-adjusted life years with the MiniMed 780G system versus MDI + CGM. The MiniMed 780G system was therefore cost-effective, assuming a willingness-to-pay threshold of JPY 5,000,000 per QALY. Although treatment costs were found to be JPY 16,226,167 higher for the MiniMed 780G, costs associated with managing long-term complications were lower. A probabilistic sensitivity analysis found the intervention to have a 76.9% probability of being cost-effective in Japan. CONCLUSION: The MiniMed 780G system was projected to be cost-effective in the management of people with T1D in Japan with HbA1c above target levels. Its use was also predicted to improve clinical outcomes when compared with MDI + CGM.

Authors

Institutions

Publication Details

Journal
Journal of Diabetes Investigation
Published
2026-10-31
DOI
https://doi.org/10.1111/jdi.70459
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cost‐effectiveness analysis comparing advanced hybrid closed‐loop automated insulin delivery with multiple daily insulin injections and continuous glucose monitoring in adults with type 1 diabetes in Japan

Yushi Hirota, Atsuhito Tone, Noriko Kodani, Simona de Portu et al.
Journal of Diabetes Investigation
Diabetes Management and Research
article

Cost‐effectiveness analysis comparing advanced hybrid closed‐loop automated insulin delivery with multiple daily insulin injections and continuous glucose monitoring in adults with type 1 diabetes in Japan

Yushi Hirota, Atsuhito Tone, Noriko Kodani, Simona de Portu, Richard Fulton Pollock, Asli Zeynep Ozdemir Saltik, Michelle Hill, Martin Field
article en

Abstract

AIM: The use of automated insulin delivery systems, including the MiniMed™ 780G advanced hybrid closed-loop system, has been shown to improve glycemic management in people with type 1 diabetes (T1D). The aim was to assess the cost-effectiveness of the MiniMed 780G system versus multiple daily injections (MDI) of insulin in combination with continuous glucose monitoring (CGM) in the management of people with T1D with elevated HbA1c levels in Japan. METHODS: Modeling was performed using the IQVIA Core Diabetes Model and clinical input data were sourced from a randomized controlled trial. A time horizon of 55 years, a discount rate of 2.0% per annum, and a payer perspective were used. Sensitivity analyses were used to examine the robustness of base-case results. RESULTS: In the base-case, an incremental cost-effectiveness ratio (ICER) of JPY 4,723,991 per quality-adjusted life year (QALY) gained was found, with an incremental benefit of 2.83 quality-adjusted life years with the MiniMed 780G system versus MDI + CGM. The MiniMed 780G system was therefore cost-effective, assuming a willingness-to-pay threshold of JPY 5,000,000 per QALY. Although treatment costs were found to be JPY 16,226,167 higher for the MiniMed 780G, costs associated with managing long-term complications were lower. A probabilistic sensitivity analysis found the intervention to have a 76.9% probability of being cost-effective in Japan. CONCLUSION: The MiniMed 780G system was projected to be cost-effective in the management of people with T1D in Japan with HbA1c above target levels. Its use was also predicted to improve clinical outcomes when compared with MDI + CGM.

Journal of Diabetes Investigation
National Center for Global Health and Medicine (JP), Okayama Saiseikai General Hospital (JP), Medtronic (Switzerland) (CH), Covalence Research (GB), Japan Institute for Health Security (JP), Kobe University (JP)
Openalex Percentile: Top 10%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon