Ultrasonographic Pupil Assessment in Patients With Severe Traumatic Brain Injury

BACKGROUND: In patients with severe traumatic brain injury, accurate pupillary assessment is critical for neurological monitoring but is often hindered by periorbital edema, trauma, or dressings that preclude direct visualization. OBJECTIVE: To validate the feasibility and accuracy of ultrasonographic pupil assessment performed through the closed eyelid as an alternative to direct pupillometry in patients with traumatic brain injury. METHODS: This prospective study enrolled 45 intensive care unit patients (36 male; mean [SD] age, 67.1 [12.9] years). Both direct pupillometry and ultrasonographic pupil assessment were sequentially completed within a 3-minute interval under standardized low-light conditions for both eyes. Direct pupillometry involved video recording of the exposed pupil with a calibrated reference scale. Ultrasonographic pupil assessment was performed by using a high-frequency linear probe placed on the closed eyelid. The primary outcome was the agreement between methods for calculating the percentage of pupillary constriction. Secondary outcomes included agreement on resting and minimum pupil diameters. RESULTS: Ultrasonographic pupil assessment showed excellent agreement with direct pupillometry for percent pupillary constriction (median [IQR] difference, 0.44% [-2.78% to 2.83%]; Wilcoxon P ≥ .48). Bland-Altman analysis showed narrow limits of agreement. Strong correlations were also noted for resting and minimum pupil diameters (0.6 ≤ r2 ≤ 0.873). CONCLUSION: Ultrasonographic pupil assessment is a reliable and accurate method for objective pupillary evaluation when direct visualization is obstructed. By enabling quantitative measurement of the pupillary light reflex through the closed eyelid, ultrasonographic pupil assessment addresses an important monitoring gap in the management of patients with severe traumatic brain injury and periorbital swelling.

Authors

Institutions

Publication Details

Journal
American Journal of Critical Care
Published
2026-11-01
DOI
https://doi.org/10.4037/ajcc2026776
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasonographic Pupil Assessment in Patients With Severe Traumatic Brain Injury

Danjiang Dong, Ling Yuan, Yan Xu, Rujing Bai et al.
1 links
American Journal of Critical Care
Ultrasound in Clinical Applications
article

Ultrasonographic Pupil Assessment in Patients With Severe Traumatic Brain Injury

Danjiang Dong, Ling Yuan, Yan Xu, Rujing Bai, Bo Feng, Qian Shi, Niannian Liu
article en

Abstract

BACKGROUND: In patients with severe traumatic brain injury, accurate pupillary assessment is critical for neurological monitoring but is often hindered by periorbital edema, trauma, or dressings that preclude direct visualization. OBJECTIVE: To validate the feasibility and accuracy of ultrasonographic pupil assessment performed through the closed eyelid as an alternative to direct pupillometry in patients with traumatic brain injury. METHODS: This prospective study enrolled 45 intensive care unit patients (36 male; mean [SD] age, 67.1 [12.9] years). Both direct pupillometry and ultrasonographic pupil assessment were sequentially completed within a 3-minute interval under standardized low-light conditions for both eyes. Direct pupillometry involved video recording of the exposed pupil with a calibrated reference scale. Ultrasonographic pupil assessment was performed by using a high-frequency linear probe placed on the closed eyelid. The primary outcome was the agreement between methods for calculating the percentage of pupillary constriction. Secondary outcomes included agreement on resting and minimum pupil diameters. RESULTS: Ultrasonographic pupil assessment showed excellent agreement with direct pupillometry for percent pupillary constriction (median [IQR] difference, 0.44% [-2.78% to 2.83%]; Wilcoxon P ≥ .48). Bland-Altman analysis showed narrow limits of agreement. Strong correlations were also noted for resting and minimum pupil diameters (0.6 ≤ r2 ≤ 0.873). CONCLUSION: Ultrasonographic pupil assessment is a reliable and accurate method for objective pupillary evaluation when direct visualization is obstructed. By enabling quantitative measurement of the pupillary light reflex through the closed eyelid, ultrasonographic pupil assessment addresses an important monitoring gap in the management of patients with severe traumatic brain injury and periorbital swelling.

American Journal of Critical CareVol. 35(6)
Nanjing Drum Tower Hospital (CN)
Good health and well-being
Openalex Percentile: Top 11%
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon