Failure Mode and Effects Analysis of Choke and Gate Valves In A Back Pressure Manifold

Choke and gate valves are critical components of a back pressure manifold (BPM), supporting pressure regulation, flow control, and isolation during drilling operations. Their failure may compromise well-control reliability and operational safety. This study identifies and prioritizes failure modes of choke and gate valves using a workshop-based Failure Mode and Effects Analysis (FMEA). Data were obtained from workshop observations, hydrostatic testing, maintenance documentation, and consensus assessments by three maintenance personnel. Four choke-valve and five gate-valve failure modes were evaluated based on severity, occurrence, and detection ratings, from which Risk Priority Numbers (RPNs) were calculated. The results showed that choke-valve seat erosion or wear had the highest RPN of 324, followed by leakage, erosion, or wear at the gate/seat-ring interface with an RPN of 225, and sticking or unresponsive operation of the choke-valve stem and actuator with an RPN of 210. The choke valve exhibited a higher average RPN than the gate valve because its throttling function exposes internal components to substantial pressure drops, accelerated flow, turbulence, and possible particle-induced erosion. The findings demonstrate that sealing-surface integrity and valve-operating reliability are the main maintenance priorities. Maintenance strategies should combine RPN ranking with severity assessment and incorporate internal visual inspection, hydrostatic and functional testing, dimensional examination, cleaning, lubrication verification, and targeted nondestructive testing. Although the identified degradation mechanisms require further verification, this study provides a structured basis for prioritizing BPM valve inspection and maintenance.

Authors

Institutions

Publication Details

Journal
Journal of Emerging Supply Chain Clean Energy and Process Engineering
Published
2026-10-31
DOI
https://doi.org/10.57102/jescee.v5i2.163
Primary Topic
Drilling and Well Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Failure Mode and Effects Analysis of Choke and Gate Valves In A Back Pressure Manifold

Khusnun Widiyati
Journal of Emerging Supply Chain Clean Energy and Process Engineering
Drilling and Well Engineering
article

Failure Mode and Effects Analysis of Choke and Gate Valves In A Back Pressure Manifold

Khusnun Widiyati
article en

Abstract

Choke and gate valves are critical components of a back pressure manifold (BPM), supporting pressure regulation, flow control, and isolation during drilling operations. Their failure may compromise well-control reliability and operational safety. This study identifies and prioritizes failure modes of choke and gate valves using a workshop-based Failure Mode and Effects Analysis (FMEA). Data were obtained from workshop observations, hydrostatic testing, maintenance documentation, and consensus assessments by three maintenance personnel. Four choke-valve and five gate-valve failure modes were evaluated based on severity, occurrence, and detection ratings, from which Risk Priority Numbers (RPNs) were calculated. The results showed that choke-valve seat erosion or wear had the highest RPN of 324, followed by leakage, erosion, or wear at the gate/seat-ring interface with an RPN of 225, and sticking or unresponsive operation of the choke-valve stem and actuator with an RPN of 210. The choke valve exhibited a higher average RPN than the gate valve because its throttling function exposes internal components to substantial pressure drops, accelerated flow, turbulence, and possible particle-induced erosion. The findings demonstrate that sealing-surface integrity and valve-operating reliability are the main maintenance priorities. Maintenance strategies should combine RPN ranking with severity assessment and incorporate internal visual inspection, hydrostatic and functional testing, dimensional examination, cleaning, lubrication verification, and targeted nondestructive testing. Although the identified degradation mechanisms require further verification, this study provides a structured basis for prioritizing BPM valve inspection and maintenance.

Journal of Emerging Supply Chain Clean Energy and Process EngineeringVol. 5(2)
Universitas Pertamina (ID)
Openalex Percentile: Top 19%
Drilling and Well Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon