PID-Based Temperature and Level Control of a Process Tank Using a Siemens PLC Training Kit

Temperature and level are among the most common controlled variables in process industries. This paper describes a closed-loop PID control system for the temperature and level of a process tank designed for a Siemens PLC training kit and evaluated by simulation. Analog sensor signals are scaled to engineering units inside the PLC, and PID algorithms drive a heating element and a pump or valve. The controller is tuned from simulated step-response tests and assessed by rise time, overshoot, settling time and steady-state error. In simulation the temperature loop reached a 90 % rise time of 340 s with 0.0 % overshoot and a steady-state error of -0.002 °C, and the level loop settled in 64 s without steady-state error.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-10-31
DOI
https://doi.org/10.5281/zenodo.23835165
Primary Topic
Advanced Control Systems Design
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

PID-Based Temperature and Level Control of a Process Tank Using a Siemens PLC Training Kit

Sahetnur Durdyyev, Yslam Orazov, Rahym Garrybaýew
Zenodo (CERN European Organization for Nuclear Research)
Advanced Control Systems Design
preprint

PID-Based Temperature and Level Control of a Process Tank Using a Siemens PLC Training Kit

Sahetnur Durdyyev, Yslam Orazov, Rahym Garrybaýew
preprint en

Abstract

Temperature and level are among the most common controlled variables in process industries. This paper describes a closed-loop PID control system for the temperature and level of a process tank designed for a Siemens PLC training kit and evaluated by simulation. Analog sensor signals are scaled to engineering units inside the PLC, and PID algorithms drive a heating element and a pump or valve. The controller is tuned from simulated step-response tests and assessed by rise time, overshoot, settling time and steady-state error. In simulation the temperature loop reached a 90 % rise time of 340 s with 0.0 % overshoot and a steady-state error of -0.002 °C, and the level loop settled in 64 s without steady-state error.

Zenodo (CERN European Organization for Nuclear Research)
Oguz Han Engineering and Technology University of Turkmenistan (TM)
Advanced Control Systems Design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.