Remote Monitoring and Control of an Industrial Process via a Siemens PLC Training Kit

Remote access to industrial processes allows operators to supervise plants without being on site, but it also introduces communication and security issues. This paper describes a remote monitoring and control system for an industrial process based on a Siemens PLC training kit and an Ethernet-based communication link. Process values are read and setpoints written from a supervisory interface, and the delay, reliability and security configuration of the link are evaluated. In simulation, process values reached the supervisory computer with a mean latency of 39 ms (maximum 257 ms) over a one-hour test, and the PLC entered its safe state in every simulated interruption longer than 5 s.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-10-31
DOI
https://doi.org/10.5281/zenodo.23835169
Primary Topic
Industrial Automation and Control Systems
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Remote Monitoring and Control of an Industrial Process via a Siemens PLC Training Kit

Sahetnur Durdyyev, Yslam Orazov, Salyh Kadyrow
Zenodo (CERN European Organization for Nuclear Research)
Industrial Automation and Control Systems
preprint

Remote Monitoring and Control of an Industrial Process via a Siemens PLC Training Kit

Sahetnur Durdyyev, Yslam Orazov, Salyh Kadyrow
preprint en

Abstract

Remote access to industrial processes allows operators to supervise plants without being on site, but it also introduces communication and security issues. This paper describes a remote monitoring and control system for an industrial process based on a Siemens PLC training kit and an Ethernet-based communication link. Process values are read and setpoints written from a supervisory interface, and the delay, reliability and security configuration of the link are evaluated. In simulation, process values reached the supervisory computer with a mean latency of 39 ms (maximum 257 ms) over a one-hour test, and the PLC entered its safe state in every simulated interruption longer than 5 s.

Zenodo (CERN European Organization for Nuclear Research)
Oguz Han Engineering and Technology University of Turkmenistan (TM)
Industrial Automation and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon