Prevalence, Risk Factors, and Outcomes of Radiographically Detected Void Formation Following Lateral Sinus Floor Elevation: A Retrospective Study

ABSTRACT Objectives To investigate the prevalence, risk factors, and impact of void formation within graft materials following lateral sinus floor elevation (LSFE) on long‐term implant survival. Materials and Methods This retrospective study analyzed 307 patients who underwent LSFE between 2018 and 2023. Voids were identified on 6‐month postoperative cone‐beam computed tomography (CBCT), and patient‐, anatomical‐, and surgery‐related variables were assessed. Least Absolute Shrinkage and Selection Operator (LASSO) regression and multivariable logistic regression were used to identify independent risk factors. Implant survival in void versus non‐void groups was compared using Kaplan–Meier analysis and the log‐rank test. Results Voids were detected in 31.3% of cases (96/307). Three independent risk factors were identified: a specific graft material (OR = 4.02, 95% CI: 1.73–9.33, p = 0.001), increased graft amount (OR = 2.20, 95% CI: 1.20–4.01, p = 0.011), and a smaller sinus mucosa tension angle (SMTA; OR = 0.98, 95% CI: 0.96–1.00, p = 0.027). In a sensitivity analysis confined to conventional graft materials, graft material amount remained robust (OR = 2.02, p = 0.025), with Stage III periodontitis, multiple‐tooth units, and endo‐sinus bone gain additionally identified, whereas membrane perforation was unexpectedly protective (OR = 0.30, p = 0.049). Over a mean 46.6‐month follow‐up, voids were significantly associated with a higher implant failure rate (7.3% vs. 1.9%) and reduced cumulative survival ( p = 0.014). Conclusions Radiographically detected voids following LSFE are associated with increased implant failure and lower cumulative survival. Void formation was independently associated with graft composition, graft material amount, and SMTA; the association with graft material amount persisted after excluding one specific material. Membrane perforation showed an unexpected protective association requiring prospective validation.

Authors

Institutions

Publication Details

Journal
Clinical Oral Implants Research
Published
2026-10-31
DOI
https://doi.org/10.1111/clr.70197
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prevalence, Risk Factors, and Outcomes of Radiographically Detected Void Formation Following Lateral Sinus Floor Elevation: A Retrospective Study

Kaichen Lai, Guoli Yang, 王志康, Yue Xi et al.
Clinical Oral Implants Research
Dental Implant Techniques and Outcomes
article

Prevalence, Risk Factors, and Outcomes of Radiographically Detected Void Formation Following Lateral Sinus Floor Elevation: A Retrospective Study

Kaichen Lai, Guoli Yang, 王志康, Yue Xi, Xiaoru Qin, Qifeng Jiang, Xuanru Jin, Xinyuan Qu, Ying Wang
article en

Abstract

ABSTRACT Objectives To investigate the prevalence, risk factors, and impact of void formation within graft materials following lateral sinus floor elevation (LSFE) on long‐term implant survival. Materials and Methods This retrospective study analyzed 307 patients who underwent LSFE between 2018 and 2023. Voids were identified on 6‐month postoperative cone‐beam computed tomography (CBCT), and patient‐, anatomical‐, and surgery‐related variables were assessed. Least Absolute Shrinkage and Selection Operator (LASSO) regression and multivariable logistic regression were used to identify independent risk factors. Implant survival in void versus non‐void groups was compared using Kaplan–Meier analysis and the log‐rank test. Results Voids were detected in 31.3% of cases (96/307). Three independent risk factors were identified: a specific graft material (OR = 4.02, 95% CI: 1.73–9.33, p = 0.001), increased graft amount (OR = 2.20, 95% CI: 1.20–4.01, p = 0.011), and a smaller sinus mucosa tension angle (SMTA; OR = 0.98, 95% CI: 0.96–1.00, p = 0.027). In a sensitivity analysis confined to conventional graft materials, graft material amount remained robust (OR = 2.02, p = 0.025), with Stage III periodontitis, multiple‐tooth units, and endo‐sinus bone gain additionally identified, whereas membrane perforation was unexpectedly protective (OR = 0.30, p = 0.049). Over a mean 46.6‐month follow‐up, voids were significantly associated with a higher implant failure rate (7.3% vs. 1.9%) and reduced cumulative survival ( p = 0.014). Conclusions Radiographically detected voids following LSFE are associated with increased implant failure and lower cumulative survival. Void formation was independently associated with graft composition, graft material amount, and SMTA; the association with graft material amount persisted after excluding one specific material. Membrane perforation showed an unexpected protective association requiring prospective validation.

Clinical Oral Implants Research
Zhejiang University Medical College Affiliated Stomatological Hospital (CN), Zhejiang University (CN)
Openalex Percentile: Top 10%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon