Authentic Sources, Potentially Unsafe Conclusions: Evidence Traceability Does Not Ensure Clinical Reliability in Retrieval-Augmented Generation for Perioperative IBD

Purpose: Retrieval-augmented generation (RAG) is increasingly used to reduce hallucination in medical large language models (LLMs), but authentic retrieval does not necessarily ensure clinically correct output. We evaluated whether full-text-enriched RAG improves the clinical reliability of locally deployed models for perioperative inflammatory bowel disease (IBD) question answering. Methods: We constructed a locally deployed full-text IBD perioperative knowledge base and a 50-question high-difficulty benchmark. Two 8B models (Qwen3-VL-8B and DeepSeek-R1-Distill-Llama-8B) were evaluated under matched no-retrieval and RAG conditions. Three physicians independently scored clinical accuracy, patient safety, and faithfulness under a source-blinded, format-homogeneous protocol. Evidence traceability was assessed objectively by verifying all retrieved PubMed identifiers (PMIDs) against PubMed. Results: All retrieved PMIDs existed in PubMed (236 verifications; 187 unique), confirming source-existence authenticity at the retrieval layer. RAG significantly improved Qwen3 accuracy (Δ=+0.44, P< 0.001) but not DeepSeek accuracy (Δ=+0.21, P=0.09), and the model-by-retrieval interaction for accuracy was not significant. Patient safety showed no reliable benefit. Faithfulness decreased significantly with RAG on Qwen3 (Δ=− 0.24, P< 0.001), with a significant model-by-retrieval interaction. Inter-rater reliability was excellent (ICC 0.86– 0.93). Conclusion: PubMed-based retrieval achieved source-existence authenticity but did not consistently improve clinical correctness or safety. Authentic references could accompany incorrect or unsafe conclusions, indicating that evidence traceability and clinical reliability should be evaluated separately. Additional model-external safety mechanisms may be warranted in high-risk settings but require independent validation. Keywords: retrieval-augmented generation, RAG, large language models, LLMs, hallucination, inflammatory bowel disease, IBD, perioperative medicine, patient safety, on-premises deployment

Authors

Institutions

Publication Details

Journal
Journal of Multidisciplinary Healthcare
Published
2026-10-31
DOI
https://doi.org/10.2147/jmdh.s640102
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Authentic Sources, Potentially Unsafe Conclusions: Evidence Traceability Does Not Ensure Clinical Reliability in Retrieval-Augmented Generation for Perioperative IBD

Wenjing Hu, Liang Sun, Baojun Huang, Yaoyao Cai
Journal of Multidisciplinary Healthcare
Artificial Intelligence in Healthcare and Education
article

Authentic Sources, Potentially Unsafe Conclusions: Evidence Traceability Does Not Ensure Clinical Reliability in Retrieval-Augmented Generation for Perioperative IBD

Wenjing Hu, Liang Sun, Baojun Huang, Yaoyao Cai
article en

Abstract

Purpose: Retrieval-augmented generation (RAG) is increasingly used to reduce hallucination in medical large language models (LLMs), but authentic retrieval does not necessarily ensure clinically correct output. We evaluated whether full-text-enriched RAG improves the clinical reliability of locally deployed models for perioperative inflammatory bowel disease (IBD) question answering. Methods: We constructed a locally deployed full-text IBD perioperative knowledge base and a 50-question high-difficulty benchmark. Two 8B models (Qwen3-VL-8B and DeepSeek-R1-Distill-Llama-8B) were evaluated under matched no-retrieval and RAG conditions. Three physicians independently scored clinical accuracy, patient safety, and faithfulness under a source-blinded, format-homogeneous protocol. Evidence traceability was assessed objectively by verifying all retrieved PubMed identifiers (PMIDs) against PubMed. Results: All retrieved PMIDs existed in PubMed (236 verifications; 187 unique), confirming source-existence authenticity at the retrieval layer. RAG significantly improved Qwen3 accuracy (Δ=+0.44, P< 0.001) but not DeepSeek accuracy (Δ=+0.21, P=0.09), and the model-by-retrieval interaction for accuracy was not significant. Patient safety showed no reliable benefit. Faithfulness decreased significantly with RAG on Qwen3 (Δ=− 0.24, P< 0.001), with a significant model-by-retrieval interaction. Inter-rater reliability was excellent (ICC 0.86– 0.93). Conclusion: PubMed-based retrieval achieved source-existence authenticity but did not consistently improve clinical correctness or safety. Authentic references could accompany incorrect or unsafe conclusions, indicating that evidence traceability and clinical reliability should be evaluated separately. Additional model-external safety mechanisms may be warranted in high-risk settings but require independent validation. Keywords: retrieval-augmented generation, RAG, large language models, LLMs, hallucination, inflammatory bowel disease, IBD, perioperative medicine, patient safety, on-premises deployment

Journal of Multidisciplinary HealthcareVol. Volume 19
Wenzhou Medical University (CN), First Affiliated Hospital of Wenzhou Medical University (CN)
Openalex Percentile: Top 19%
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon