EMERGENCY MESH HERNIOPLASTY WITH ADHESIOLYSIS IN OBSTRUCTED INCISIONAL HERNIA WITH MULTIPLE FASCIAL DEFECTS FOLLOWING TUBAL LIGATION: A CASE REPORT

Introduction: Obstructed incisional hernia is a potentially serious complication of previous abdominal surgery and requires timely assessment and appropriate surgical management. The presence of multiple fascial defects and dense intra-abdominal adhesions can make emergency exploration technically challenging and increases the risk of bowel injury. The use of prosthetic mesh in emergency hernia repair requires careful assessment of bowel viability and the degree of contamination. Case Presentation: A 46-year-old female presented with acute-onset lower abdominal pain and a tender, irreducible swelling at the site of a previous operative scar following tubal ligation approximately 10 years earlier. Ultrasonography demonstrated a bowel-containing incisional hernia with features suggestive of obstruction. The patient was hemodynamically stable, with no clinical evidence of generalized peritonitis. Intervention: Emergency surgical exploration was performed. Multiple fascial defects with dense adhesions between the bowel loops and anterior abdominal wall were identified. Careful adhesiolysis was performed, and the obstructed small-bowel loops were reduced after confirming viability. There was no gangrene, perforation, or gross contamination. The multiple defects were delineated and repaired using tension-free polypropylene mesh with adequate overlap. Outcome: The postoperative recovery was uneventful. The patient tolerated gradual reintroduction of oral intake and was mobilized appropriately. No surgical-site infection, mesh-related complication, or clinically significant seroma was observed during the reported postoperative period. The patient was discharged in stable condition. At follow-up, she remained asymptomatic without recurrent swelling or obstructive symptoms. Follow-up duration: 6 weeks. Conclusion: Emergency mesh repair may be considered in carefully selected patients with obstructed incisional hernia when the bowel remains viable and the operative field is suitable for prosthetic mesh placement. Identification of all fascial defects, meticulous adhesiolysis, assessment of bowel viability, adequate mesh overlap, and tension-free fixation are important for successful repair.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-01
DOI
https://doi.org/10.5281/zenodo.23829050
Primary Topic
Hernia repair and management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EMERGENCY MESH HERNIOPLASTY WITH ADHESIOLYSIS IN OBSTRUCTED INCISIONAL HERNIA WITH MULTIPLE FASCIAL DEFECTS FOLLOWING TUBAL LIGATION: A CASE REPORT

Dr. Rashmi A. Kale2 Dr. Saiprasad B. Kottawar*1
1 links
Zenodo (CERN European Organization for Nuclear Research)
Hernia repair and management
article

EMERGENCY MESH HERNIOPLASTY WITH ADHESIOLYSIS IN OBSTRUCTED INCISIONAL HERNIA WITH MULTIPLE FASCIAL DEFECTS FOLLOWING TUBAL LIGATION: A CASE REPORT

Dr. Rashmi A. Kale2 Dr. Saiprasad B. Kottawar*1
article en

Abstract

Introduction: Obstructed incisional hernia is a potentially serious complication of previous abdominal surgery and requires timely assessment and appropriate surgical management. The presence of multiple fascial defects and dense intra-abdominal adhesions can make emergency exploration technically challenging and increases the risk of bowel injury. The use of prosthetic mesh in emergency hernia repair requires careful assessment of bowel viability and the degree of contamination. Case Presentation: A 46-year-old female presented with acute-onset lower abdominal pain and a tender, irreducible swelling at the site of a previous operative scar following tubal ligation approximately 10 years earlier. Ultrasonography demonstrated a bowel-containing incisional hernia with features suggestive of obstruction. The patient was hemodynamically stable, with no clinical evidence of generalized peritonitis. Intervention: Emergency surgical exploration was performed. Multiple fascial defects with dense adhesions between the bowel loops and anterior abdominal wall were identified. Careful adhesiolysis was performed, and the obstructed small-bowel loops were reduced after confirming viability. There was no gangrene, perforation, or gross contamination. The multiple defects were delineated and repaired using tension-free polypropylene mesh with adequate overlap. Outcome: The postoperative recovery was uneventful. The patient tolerated gradual reintroduction of oral intake and was mobilized appropriately. No surgical-site infection, mesh-related complication, or clinically significant seroma was observed during the reported postoperative period. The patient was discharged in stable condition. At follow-up, she remained asymptomatic without recurrent swelling or obstructive symptoms. Follow-up duration: 6 weeks. Conclusion: Emergency mesh repair may be considered in carefully selected patients with obstructed incisional hernia when the bowel remains viable and the operative field is suitable for prosthetic mesh placement. Identification of all fascial defects, meticulous adhesiolysis, assessment of bowel viability, adequate mesh overlap, and tension-free fixation are important for successful repair.

Zenodo (CERN European Organization for Nuclear Research)
Good health and well-being
Openalex Percentile: Top 10%
Hernia repair and management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon