EXPRESS: High-Accuracy Thermal Diffusivity Measurements by Steady-State and Time Resolved Thermal Lensing: Methodology and Application to Nanoparticle Dispersions

< 0.001) homogeneous solutions. Accurate photothermal measurements for multicomponent homogeneous and heterogeneous systems are complicated by multifactorial metrological control. The dependence of the characteristic thermal lens development time on the irradiation time is highly sensitive to side effects, such as thermal (thermophoresis) and optical (dynamic changes in light absorption). This paper examines the behavior of the characteristic time of thermal field development for homogeneous dye solutions (Sudan 1 in ethanol and ferroin in water), nanoparticle dispersions (silicon oxide and graphene, mixed iron oxide, and polystyrene), and photosensitive systems (boron subporphyrazine and substituted lutetium phthalocyanine) depending on the nature of the sample and the most significant instrumental factors. It is shown that the choice of thermal lens pumping and dissipation times and the achievement of a steady state for time-resolved measurements play a key role in the accuracy of thermal-lens thermal diffusivity measurements. The potential for using the characteristic time function to verify the accuracy of photothermal measurements of various types of samples is demonstrated. It is established that the first 5-10 ms of the characteristic time function development occur due to the thermal properties of the solvent. The change in the characteristic development time of the thermal lens of the first 5-10 ms is the result of the influence of high optical absorption or non-optimal conditions of the photothermal experiment, leading to a systematic error of more than 5%. These methodological advances are particularly valuable for accurate characterization of nanoparticle thermal transport and are essential for developing advanced nanofluidic and photothermal systems where the accuracy of thermal properties directly impacts material performance.

Authors

Publication Details

Journal
Applied Spectroscopy
Published
2026-10-30
DOI
https://doi.org/10.1177/00037028261506405
Primary Topic
Thermography and Photoacoustic Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EXPRESS: High-Accuracy Thermal Diffusivity Measurements by Steady-State and Time Resolved Thermal Lensing: Methodology and Application to Nanoparticle Dispersions

Мikhail А. Proskurnin, Vladislav R. Khabibullin, Evgeniya Yu. Afonyushkina
Applied Spectroscopy
Thermography and Photoacoustic Techniques
article

EXPRESS: High-Accuracy Thermal Diffusivity Measurements by Steady-State and Time Resolved Thermal Lensing: Methodology and Application to Nanoparticle Dispersions

Мikhail А. Proskurnin, Vladislav R. Khabibullin, Evgeniya Yu. Afonyushkina
article en

Abstract

< 0.001) homogeneous solutions. Accurate photothermal measurements for multicomponent homogeneous and heterogeneous systems are complicated by multifactorial metrological control. The dependence of the characteristic thermal lens development time on the irradiation time is highly sensitive to side effects, such as thermal (thermophoresis) and optical (dynamic changes in light absorption). This paper examines the behavior of the characteristic time of thermal field development for homogeneous dye solutions (Sudan 1 in ethanol and ferroin in water), nanoparticle dispersions (silicon oxide and graphene, mixed iron oxide, and polystyrene), and photosensitive systems (boron subporphyrazine and substituted lutetium phthalocyanine) depending on the nature of the sample and the most significant instrumental factors. It is shown that the choice of thermal lens pumping and dissipation times and the achievement of a steady state for time-resolved measurements play a key role in the accuracy of thermal-lens thermal diffusivity measurements. The potential for using the characteristic time function to verify the accuracy of photothermal measurements of various types of samples is demonstrated. It is established that the first 5-10 ms of the characteristic time function development occur due to the thermal properties of the solvent. The change in the characteristic development time of the thermal lens of the first 5-10 ms is the result of the influence of high optical absorption or non-optimal conditions of the photothermal experiment, leading to a systematic error of more than 5%. These methodological advances are particularly valuable for accurate characterization of nanoparticle thermal transport and are essential for developing advanced nanofluidic and photothermal systems where the accuracy of thermal properties directly impacts material performance.

Applied Spectroscopy
Openalex Percentile: Top 23%
Thermography and Photoacoustic Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
EXPRESS: High-Accuracy Thermal Diffusivity Measurements by Steady-State and Time Resolved Thermal Lensing: Methodology and Application to Nanoparticle Dispersions — Мikhail А. Proskurnin, Vladislav R. Khabibullin, et al. · Applied Spectroscopy (2026) | TGRS Research Map | TGRS