Visual rigid laryngoscope versus Macintosh laryngoscope using low-dose relaxants in thyroid surgery

Objective This study evaluated the safety and efficacy of the Macintosh laryngoscope versus the visual rigid laryngoscope (VRL) for tracheal intubation under a low-dose muscle relaxant protocol in thyroid surgery, to provide clinical evidence for the selection of optimal intubation tools for this setting. Methods In this single-center, randomized controlled trial, two experienced anesthesiologists performed tracheal intubation using either the Macintosh laryngoscope (Mac group, n = 47) or VRL (VRL group, n = 45) in patients undergoing elective thyroid surgery with Intraoperative neuromonitoring (IONM). The primary outcome was intubation time. Secondary outcomes included first-attempt intubation success rate, hemodynamic changes during the peri-intubation period, laryngoscopic view graded by the Cormack-Lehane classification, and intubation-related complications. Results The intubation time was significantly shorter in the VRL group (mean ± SD, 33.27 ± 8.36 s) than in the Mac group (52.19 ± 9.83 s) ( P < 0.001). The intubation success rate and heart rates did not differ between groups ( P > 0.05). The mean arterial pressure (MAP) at intubation and the amplitude of MAP increase during intubation was lower in Group VRL than in Group Mac ( P < 0.005). No statistically significant differences were observed between the two groups in peripheral oxygen saturation (SpO 2 ), Cormack-Lehane classification, or intubation-related complications ( P > 0.05). Conclusion For thyroid surgery using a low-dose muscle relaxant protocol to enable IONM, the VRL provides significantly shorter intubation time and better hemodynamic stability at intubation compared with the Macintosh laryngoscope. No significant differences were observed between the two devices in intubation success rate, laryngoscopic view, or intubation-related complications.

Authors

Institutions

Publication Details

Journal
PeerJ
Published
2026-10-30
DOI
https://doi.org/10.7717/peerj.21893
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Visual rigid laryngoscope versus Macintosh laryngoscope using low-dose relaxants in thyroid surgery

高友光, Binmei Yu, Bo Lin, Cailing Guo et al.
PeerJ
Airway Management and Intubation Techniques
article

Visual rigid laryngoscope versus Macintosh laryngoscope using low-dose relaxants in thyroid surgery

高友光, Binmei Yu, Bo Lin, Cailing Guo, Weihuang Qiu, Xianzhong Lin, Tingjie Wang, Lijun Weng, Menglu Shi
article en

Abstract

Objective This study evaluated the safety and efficacy of the Macintosh laryngoscope versus the visual rigid laryngoscope (VRL) for tracheal intubation under a low-dose muscle relaxant protocol in thyroid surgery, to provide clinical evidence for the selection of optimal intubation tools for this setting. Methods In this single-center, randomized controlled trial, two experienced anesthesiologists performed tracheal intubation using either the Macintosh laryngoscope (Mac group, n = 47) or VRL (VRL group, n = 45) in patients undergoing elective thyroid surgery with Intraoperative neuromonitoring (IONM). The primary outcome was intubation time. Secondary outcomes included first-attempt intubation success rate, hemodynamic changes during the peri-intubation period, laryngoscopic view graded by the Cormack-Lehane classification, and intubation-related complications. Results The intubation time was significantly shorter in the VRL group (mean ± SD, 33.27 ± 8.36 s) than in the Mac group (52.19 ± 9.83 s) ( P < 0.001). The intubation success rate and heart rates did not differ between groups ( P > 0.05). The mean arterial pressure (MAP) at intubation and the amplitude of MAP increase during intubation was lower in Group VRL than in Group Mac ( P < 0.005). No statistically significant differences were observed between the two groups in peripheral oxygen saturation (SpO 2 ), Cormack-Lehane classification, or intubation-related complications ( P > 0.05). Conclusion For thyroid surgery using a low-dose muscle relaxant protocol to enable IONM, the VRL provides significantly shorter intubation time and better hemodynamic stability at intubation compared with the Macintosh laryngoscope. No significant differences were observed between the two devices in intubation success rate, laryngoscopic view, or intubation-related complications.

PeerJVol. 14
Fujian Medical University (CN), First Affiliated Hospital of Fujian Medical University (CN)
Natural Science Foundation of Fujian Province, Fujian Medical University
Good health and well-being
Openalex Percentile: Top 8%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon