Efficacy and safety of low-power (20 W) catheter ablation for typical atrioventricular nodal reentrant tachycardia: a prospective multicenter study

Background Atrioventricular nodal reentrant tachycardia (AVNRT) is the most common supraventricular tachycardia. Although catheter ablation is the definitive treatment, atrioventricular (AV) block requiring permanent pacemaker implantation remains a major safety concern. Objective To evaluate the efficacy and safety of a low-power (20 W) slow pathway ablation strategy for typical AVNRT. Methods In this prospective multicenter study, 203 consecutive patients (mean age 54.4 ± 17.3 years; 59.6% women) underwent slow pathway ablation initiated at 20 W, with power escalation as needed. Variables associated with requiring higher power were analyzed using univariable and multivariable logistic regression. Results Initial success at 20 W was achieved in 170 patients (83.7%); 33 patients (16.3%) required higher power, with an overall acute success rate of 99.5%. Compared with patients who achieved success at 20 W, those requiring higher power were younger and had higher pre-ablation heart rates. On univariable analysis, younger age [odds ratio [OR] 0.66 per 10-year increase, 95% confidence interval [CI] 0.54–0.83; p < 0.001] and higher pre-ablation heart rate (OR 1.88 per 10-bpm increase, 95% CI 1.30–2.73; p < 0.001) were associated with the need for higher power. Transient AV block occurred in 1.9% of patients, and no cases of permanent AV block (0%, 95% CI 0%–1.8%) or pacemaker implantation were observed. During 18.3 ± 4.1 months of follow-up, recurrence occurred in two patients (0.9%). Conclusion An initial 20 W ablation strategy provides high efficacy with a favorable safety profile and no permanent AV block observed in this cohort. Younger age and a higher baseline heart rate predicted the need for power escalation, supporting an initial low-power approach for AVNRT ablation.

Authors

Institutions

Publication Details

Journal
Frontiers in Cardiovascular Medicine
Published
2026-10-30
DOI
https://doi.org/10.3389/fcvm.2026.1949109
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacy and safety of low-power (20 W) catheter ablation for typical atrioventricular nodal reentrant tachycardia: a prospective multicenter study

Chang Hee Kwon, In Geol Song, Lae‐Young Jung, Minsu Kim et al.
Frontiers in Cardiovascular Medicine
Cardiac Arrhythmias and Treatments
article

Efficacy and safety of low-power (20 W) catheter ablation for typical atrioventricular nodal reentrant tachycardia: a prospective multicenter study

Chang Hee Kwon, In Geol Song, Lae‐Young Jung, Minsu Kim, Ji Hyun Lee
article en

Abstract

Background Atrioventricular nodal reentrant tachycardia (AVNRT) is the most common supraventricular tachycardia. Although catheter ablation is the definitive treatment, atrioventricular (AV) block requiring permanent pacemaker implantation remains a major safety concern. Objective To evaluate the efficacy and safety of a low-power (20 W) slow pathway ablation strategy for typical AVNRT. Methods In this prospective multicenter study, 203 consecutive patients (mean age 54.4 ± 17.3 years; 59.6% women) underwent slow pathway ablation initiated at 20 W, with power escalation as needed. Variables associated with requiring higher power were analyzed using univariable and multivariable logistic regression. Results Initial success at 20 W was achieved in 170 patients (83.7%); 33 patients (16.3%) required higher power, with an overall acute success rate of 99.5%. Compared with patients who achieved success at 20 W, those requiring higher power were younger and had higher pre-ablation heart rates. On univariable analysis, younger age [odds ratio [OR] 0.66 per 10-year increase, 95% confidence interval [CI] 0.54–0.83; p < 0.001] and higher pre-ablation heart rate (OR 1.88 per 10-bpm increase, 95% CI 1.30–2.73; p < 0.001) were associated with the need for higher power. Transient AV block occurred in 1.9% of patients, and no cases of permanent AV block (0%, 95% CI 0%–1.8%) or pacemaker implantation were observed. During 18.3 ± 4.1 months of follow-up, recurrence occurred in two patients (0.9%). Conclusion An initial 20 W ablation strategy provides high efficacy with a favorable safety profile and no permanent AV block observed in this cohort. Younger age and a higher baseline heart rate predicted the need for power escalation, supporting an initial low-power approach for AVNRT ablation.

Frontiers in Cardiovascular MedicineVol. 13
Chungnam National University (KR), Seoul National University Bundang Hospital (KR), Konkuk University Medical Center (KR), Konyang University Hospital (KR), Jeonbuk National University Hospital (KR), Chungnam National University Sejong Hospital (KR), Jeonbuk National University (KR)
Good health and well-being
Openalex Percentile: Top 11%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon