The Brachioradial Artery Variant: A Diagnostic Challenge in the Assessment of Dialysis Access-Associated Steal Syndrome

An 89-year-old woman with end-stage renal disease presented for evaluation of a new right-sided brachial-axillary arteriovenous graft (AVG). Postoperative physical examination revealed a strong, palpable radial pulse and no global hand dysfunction, suggesting adequate distal perfusion. However, duplex ultrasound identified a high-origin radial artery (brachioradial artery) that spared the thumb and index finger from the pressure gradient of the AVG, while the middle, ring, and small fingers exhibited a distinct segmental perfusion deficit. Spectral Doppler and photoplethysmography confirmed total retrograde ulnar flow that reverted to antegrade only with manual AVG compression. This case illustrates the value of duplex scanning for identifying an anatomic variant that affected the clinical presentation of steal physiology after creation of a proximal limb arteriovenous access.

Authors

Institutions

Publication Details

Journal
Journal for Vascular Ultrasound
Published
2026-10-30
DOI
https://doi.org/10.1177/15443167261497749
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Brachioradial Artery Variant: A Diagnostic Challenge in the Assessment of Dialysis Access-Associated Steal Syndrome

Jose Serrat
2 links
Journal for Vascular Ultrasound
Central Venous Catheters and Hemodialysis
article

The Brachioradial Artery Variant: A Diagnostic Challenge in the Assessment of Dialysis Access-Associated Steal Syndrome

Jose Serrat
article en

Abstract

An 89-year-old woman with end-stage renal disease presented for evaluation of a new right-sided brachial-axillary arteriovenous graft (AVG). Postoperative physical examination revealed a strong, palpable radial pulse and no global hand dysfunction, suggesting adequate distal perfusion. However, duplex ultrasound identified a high-origin radial artery (brachioradial artery) that spared the thumb and index finger from the pressure gradient of the AVG, while the middle, ring, and small fingers exhibited a distinct segmental perfusion deficit. Spectral Doppler and photoplethysmography confirmed total retrograde ulnar flow that reverted to antegrade only with manual AVG compression. This case illustrates the value of duplex scanning for identifying an anatomic variant that affected the clinical presentation of steal physiology after creation of a proximal limb arteriovenous access.

Journal for Vascular Ultrasound
Lee Memorial Health System (US)
Good health and well-being
Openalex Percentile: Top 7%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon