An IoT-Based Healthcare Monitoring and Surveillance Framework for People with Special Needs

People with special needs, such as frail older adults and people living with Parkinson’s disease (PD), heart-rhythm disorders or dementia, are often alone when a critical event happens. We present IoT-CARES, a four-layer Internet of Things (IoT) framework with one lightweight edge pipeline for five services: fall detection, activity monitoring of adults aged 70+, freezing-of-gait (FoG) detection, single-lead electrocardiogram (ECG) arrhythmia monitoring and camera-free cognitive-health surveillance. A dual-view ensemble (a fixed average of gradient-boosted trees on physiological descriptors and a linear model on random-convolution features) runs without a deep-learning runtime. A subject-level conformal calibration bounds a new person’s false-alarm rate by a carer-chosen budget with probability ≥90%, provided that new and calibration people are exchangeable, and federated learning trains shared models without moving raw data. On five open datasets (438 people), evaluated on held-out people, the framework reached an area under the receiver-operating-characteristic curve (AUROC) of 0.9998 for simulated falls and 0.908 for FoG, and a macro-F1 of 0.778 for activity; federated training matched centralised training. Personalisation helped only when the onboarding data contained the target events: five labelled ECG minutes raised arrhythmia macro-F1 from 0.667 (best global model) to 0.932, whereas fine-tuning on routine activity lowered activity macro-F1 (0.766 to 0.683) unless only the output layer was adapted (0.795). Conformal calibration kept 16 of 17 young volunteers (94.1%; 95% confidence interval 71.3–99.9%) free of false fall alarms during their activity protocol while detecting 94.6% of simulated falls (window-optimal threshold: 76.5% free of false alarms), and kept 9 of 10 people with PD within four false cues per hour; with so few people, these estimates are imprecise. In free-living data of 18 adults aged 70–95 years, a fall threshold calibrated on the volunteers raised no false alarms in 12.6 h, but calibration on the older adults’ own data detected more of the volunteers’ simulated falls (99.1% vs. 92.1%). Ambient sensors detected dementia (AUROC 0.962) but not reliably mild cognitive impairment (0.523). Inference took ≤ 24.3 ms per window on one processor core, and data leaving the home fell 219–759-fold.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-10-30
DOI
https://doi.org/10.3390/bioengineering13111289
Primary Topic
Context-Aware Activity Recognition Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An IoT-Based Healthcare Monitoring and Surveillance Framework for People with Special Needs

Mohammed Assiri
2 links
Bioengineering
Context-Aware Activity Recognition Systems
article

An IoT-Based Healthcare Monitoring and Surveillance Framework for People with Special Needs

Mohammed Assiri
article en

Abstract

People with special needs, such as frail older adults and people living with Parkinson’s disease (PD), heart-rhythm disorders or dementia, are often alone when a critical event happens. We present IoT-CARES, a four-layer Internet of Things (IoT) framework with one lightweight edge pipeline for five services: fall detection, activity monitoring of adults aged 70+, freezing-of-gait (FoG) detection, single-lead electrocardiogram (ECG) arrhythmia monitoring and camera-free cognitive-health surveillance. A dual-view ensemble (a fixed average of gradient-boosted trees on physiological descriptors and a linear model on random-convolution features) runs without a deep-learning runtime. A subject-level conformal calibration bounds a new person’s false-alarm rate by a carer-chosen budget with probability ≥90%, provided that new and calibration people are exchangeable, and federated learning trains shared models without moving raw data. On five open datasets (438 people), evaluated on held-out people, the framework reached an area under the receiver-operating-characteristic curve (AUROC) of 0.9998 for simulated falls and 0.908 for FoG, and a macro-F1 of 0.778 for activity; federated training matched centralised training. Personalisation helped only when the onboarding data contained the target events: five labelled ECG minutes raised arrhythmia macro-F1 from 0.667 (best global model) to 0.932, whereas fine-tuning on routine activity lowered activity macro-F1 (0.766 to 0.683) unless only the output layer was adapted (0.795). Conformal calibration kept 16 of 17 young volunteers (94.1%; 95% confidence interval 71.3–99.9%) free of false fall alarms during their activity protocol while detecting 94.6% of simulated falls (window-optimal threshold: 76.5% free of false alarms), and kept 9 of 10 people with PD within four false cues per hour; with so few people, these estimates are imprecise. In free-living data of 18 adults aged 70–95 years, a fall threshold calibrated on the volunteers raised no false alarms in 12.6 h, but calibration on the older adults’ own data detected more of the volunteers’ simulated falls (99.1% vs. 92.1%). Ambient sensors detected dementia (AUROC 0.962) but not reliably mild cognitive impairment (0.523). Inference took ≤ 24.3 ms per window on one processor core, and data leaving the home fell 219–759-fold.

BioengineeringVol. 13(11)
Prince Sattam Bin Abdulaziz University (SA)
Good health and well-being
Openalex Percentile: Top 17%
Context-Aware Activity Recognition Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon