A single-plane electrical impedance tomography framework for integrated liver and kidney assessment
Chronic liver and kidney diseases frequently coexist, but their assessment typically requires separate clinical workflows involving serum-based estimated glomerular filtration rate (eGFR) testing and liver elastography-based controlled attenuation parameter (CAP). Electrical impedance tomography (EIT) has recently shown promise for providing portable, non-invasive proxies for both reference measurements. However, existing multi-organ EIT assessment still requires different acquisition protocols for each organ. To simplify this procedure, we assessed the feasibility of a single-plane EIT framework for reconstructing organ-specific images and estimating liver and kidney health from one abdominal belt placement. Across diverse abdominal belt locations, opposite-plane deviation was significantly greater for eGFREIT estimates (2.92%; IQR, 0.46-12.53%) than for CAPEIT estimates (0.94%; IQR, 0.66-1.70%) (p < 0.01). For both organs, compared to images acquired at the conventional organ-specific planes, image correlation significantly decreased (both, p < 0.05) and normalized root mean squared error significantly increased (both, p < 0.05) at the furthest imaging plane, with these differences being numerically larger for the kidney. Together, these results supported the kidney plane as the preferred location for multi-organ assessment. Test-retest evaluation after belt removal and reapplication demonstrated that the correlation between two repeated CAPEIT estimates was just as strong at the kidney plane (R2 = 0.98, p < 0.001) as it was at the conventional liver plane (R2 = 0.97, p < 0.001). Finally, in an independent clinical cohort, kidney-plane CAPEIT estimates were significantly higher in participants with a high metabolic liver-risk profile (i.e. diabetes and high blood pressure) (p < 0.005). CAPEIT estimates also distinguished high and low metabolic risk groups with an AUC of 0.756. Together, these findings support the feasibility of a portable multi-organ EIT imaging framework capable of extracting complementary liver and kidney information from a single belt placement.
Authors
- Nan‐Jie Gong (ORCID: https://orcid.org/0000-0001-9249-413X)
- Bradley Jay Edelman (ORCID: https://orcid.org/0000-0002-7502-9620)
- Russell W. Chan (ORCID: https://orcid.org/0000-0003-1735-7076)
- Iris Yuwen Zhou (ORCID: https://orcid.org/0000-0002-4351-7398)
- Justin Q. J. Ge
- Aywin Wu
- Mo Kwan Ho
- Jen-Chien Lai
- Monica Wong
Institutions
- Massachusetts General Hospital (US)
- Athinoula A. Martinos Center for Biomedical Imaging (US)
- East China Normal University (CN)
Publication Details
- Journal
- bioRxiv (Cold Spring Harbor Laboratory)
- Published
- 2026-10-30
- DOI
- https://doi.org/10.64898/2026.10.26.762009
- Primary Topic
- Electrical and Bioimpedance Tomography
- Type
- preprint