Comparison of the Accuracy of the Web-Based ESCRS IOL Power Calculator Formulas

Purpose To compare the accuracy of modern and conventional intraocular lens (IOL) power calculation formulas available on the ESCRS calculator and the IOLMaster 700 using 6-month postoperative refraction, and to assess the correlation between prediction errors and preoperative biometric variables.Methods This retrospective cross-sectional study analyzed a total of 223 eyes from 223 patients undergoing cataract surgery with TECNIS Eyhance ICB00 IOL. Preoperative biometry was obtained using the IOLMaster 700 and CASIA2. Seven formulas from the ESCRS calculator and 4 conventional formulas from IOLMaster 700 were evaluated. Lens constants were optimized to achieve a mean prediction error (PE) of zero. Primary outcome measures included median absolute error (MedAE), root mean square absolute error (RMSAE), and the percentage of eyes within ±0.50 diopters (D) of prediction error. Formula Performance Index (FPI) was used to assess overall accuracy. Correlation between PE and biometric variables was examined using univariate and multivariate regression.Results All formulas demonstrated comparable refractive accuracy. MedAE ranged from 0.29 to 0.33 D (p = .921) and RMSAE from 0.416 to 0.465 D (p = .437), and 72.2% to 78.5% of eyes were within ±0.50 D (p = .776), with no statistically significant differences among formulas. FPI ranged from 0.617 (SRK/T) to 0.666 (Cooke K6). In multivariate regression, the proportion of PE variance explained by preoperative variables was lowest for Cooke K6 (R2 = 0.057) and highest for SRK/T (R2 = 0.242).Conclusions Both modern and conventional IOL formulas provided comparable refractive outcomes when lens constants were optimized and standardized biometry was used. The strength of the association between prediction error and preoperative biometric parameters varied across formulas, which merits further evaluation in studies with broader biometric representation.

Authors

Institutions

Publication Details

Journal
Seminars in Ophthalmology
Published
2026-10-30
DOI
https://doi.org/10.1080/08820538.2026.2753552
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of the Accuracy of the Web-Based ESCRS IOL Power Calculator Formulas

Nahyun Park, Chung Min Lee, Kyu Sang Eah, Alison H. Hong et al.
Seminars in Ophthalmology
Intraocular Surgery and Lenses
article

Comparison of the Accuracy of the Web-Based ESCRS IOL Power Calculator Formulas

Nahyun Park, Chung Min Lee, Kyu Sang Eah, Alison H. Hong, H W Chung, Ji Yoon Park, Ryun Hee Lee, Hun Lee, Jae Yong Kim, Yea Eun Lee, Junha Kang, Jeewon Han
article en

Abstract

Purpose To compare the accuracy of modern and conventional intraocular lens (IOL) power calculation formulas available on the ESCRS calculator and the IOLMaster 700 using 6-month postoperative refraction, and to assess the correlation between prediction errors and preoperative biometric variables.Methods This retrospective cross-sectional study analyzed a total of 223 eyes from 223 patients undergoing cataract surgery with TECNIS Eyhance ICB00 IOL. Preoperative biometry was obtained using the IOLMaster 700 and CASIA2. Seven formulas from the ESCRS calculator and 4 conventional formulas from IOLMaster 700 were evaluated. Lens constants were optimized to achieve a mean prediction error (PE) of zero. Primary outcome measures included median absolute error (MedAE), root mean square absolute error (RMSAE), and the percentage of eyes within ±0.50 diopters (D) of prediction error. Formula Performance Index (FPI) was used to assess overall accuracy. Correlation between PE and biometric variables was examined using univariate and multivariate regression.Results All formulas demonstrated comparable refractive accuracy. MedAE ranged from 0.29 to 0.33 D (p = .921) and RMSAE from 0.416 to 0.465 D (p = .437), and 72.2% to 78.5% of eyes were within ±0.50 D (p = .776), with no statistically significant differences among formulas. FPI ranged from 0.617 (SRK/T) to 0.666 (Cooke K6). In multivariate regression, the proportion of PE variance explained by preoperative variables was lowest for Cooke K6 (R2 = 0.057) and highest for SRK/T (R2 = 0.242).Conclusions Both modern and conventional IOL formulas provided comparable refractive outcomes when lens constants were optimized and standardized biometry was used. The strength of the association between prediction error and preoperative biometric parameters varied across formulas, which merits further evaluation in studies with broader biometric representation.

Seminars in Ophthalmology
Royal Free London NHS Foundation Trust (GB), George Washington University (US), Asan Medical Center (KR), University of Ulsan (KR)
Korea Health Industry Development Institute
Good health and well-being
Openalex Percentile: Top 8%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon