Compact biomedical time-domain diffuse optical spectroscopy using a commercial LiDAR sensor

Miniaturising time-domain diffuse optical spectroscopy (TD-DOS) is limited by the cost and complexity of photon-timing instrumentation. We demonstrate TD - DOS using a commercial LiDAR module integrating a 940 nm VCSEL, SPAD detector and timing electronics. A light-guide modification establishes a 20 mm source–detector separation. Using photon-count and mean-time measurements, we retrieve absorption and reduced scattering coefficients from MEDPHOT phantoms with repeatability of 1.96% and 1.55%, respectively. Forearm measurements at 4 Hz detect reversible absorption changes during cuff occlusion. These results demonstrate the feasibility of compact, low-cost TD-DOS using mass-produced LiDAR hardware.

Authors

Publication Details

Published
2026-10-30
DOI
https://doi.org/10.1364/opticaopen.34856652.v1
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Compact biomedical time-domain diffuse optical spectroscopy using a commercial LiDAR sensor

Sanathana Konugolu Venkata Sekar, Claudia Nunzia Guadagno, Suraj Kumar Kothuri, Sri Lanka et al.
1 links
Optical Imaging and Spectroscopy Techniques
preprint

Compact biomedical time-domain diffuse optical spectroscopy using a commercial LiDAR sensor

Sanathana Konugolu Venkata Sekar, Claudia Nunzia Guadagno, Suraj Kumar Kothuri, Sri Lanka, Keela Hannah Hughes, Stefan Andersson Engels
preprint en

Abstract

Miniaturising time-domain diffuse optical spectroscopy (TD-DOS) is limited by the cost and complexity of photon-timing instrumentation. We demonstrate TD - DOS using a commercial LiDAR module integrating a 940 nm VCSEL, SPAD detector and timing electronics. A light-guide modification establishes a 20 mm source–detector separation. Using photon-count and mean-time measurements, we retrieve absorption and reduced scattering coefficients from MEDPHOT phantoms with repeatability of 1.96% and 1.55%, respectively. Forearm measurements at 4 Hz detect reversible absorption changes during cuff occlusion. These results demonstrate the feasibility of compact, low-cost TD-DOS using mass-produced LiDAR hardware.

Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon