Investigation of thermal contact conductance of bolted flange structures based on experiments and finite element inverse analysis

The investigation of the thermal contact conductance (TCC) of bolted flange structures is of great significance for the thermal design optimization and service reliability of the relevant equipment. In this study, three types of bolted flange structures are utilized for the purpose of experimental investigation: aluminum alloy/aluminum alloy, aluminum alloy/stainless steel, and aluminum alloy/titanium alloy. The focus of the study is the examination of the effects of temperature, bolt torque, and material combination on TCC. Multi-factor sensitivity analysis is performed using the random forest algorithm. The results suggest that, for the bolted flange structures and experimental conditions examined in this study, the equivalent uniform TCC model produces more stable and physically consistent results. Of the three factors that were the focus of the investigation, temperature was found to have the most significant impact, accounting for 59.27% of the total feature importance. It is evident that the TCC increases concomitantly with the rise of bolt torque; however, the growth rate gradually slows down. In the present study, the three combinations under investigation were found to exhibit varying levels of TCC. The aluminum alloy/aluminum alloy interface was found to exhibit the highest level of TCC, while the aluminum alloy/titanium alloy interface was found to exhibit the lowest. The mean error of the transient simulation employing the TCC obtained by steady-state inversion is approximately 3.40% and 1.04%, which demonstrates good reliability. This study elucidates the relationships between temperature, bolt torque, material combination, and the macroscopic equivalent TCC, providing a reference for thermal analysis and thermal design of relevant engineering structures.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-10-30
DOI
https://doi.org/10.1016/j.csite.2026.108691
Primary Topic
Heat Transfer and Numerical Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of thermal contact conductance of bolted flange structures based on experiments and finite element inverse analysis

Liping Pan, Zhu He, 左嫦娥, Yang Wu et al.
Case Studies in Thermal Engineering
Heat Transfer and Numerical Methods
article

Investigation of thermal contact conductance of bolted flange structures based on experiments and finite element inverse analysis

Liping Pan, Zhu He, 左嫦娥, Yang Wu, Yawei Li, Xuecheng Xu, Yongdi Ge
article en

Abstract

The investigation of the thermal contact conductance (TCC) of bolted flange structures is of great significance for the thermal design optimization and service reliability of the relevant equipment. In this study, three types of bolted flange structures are utilized for the purpose of experimental investigation: aluminum alloy/aluminum alloy, aluminum alloy/stainless steel, and aluminum alloy/titanium alloy. The focus of the study is the examination of the effects of temperature, bolt torque, and material combination on TCC. Multi-factor sensitivity analysis is performed using the random forest algorithm. The results suggest that, for the bolted flange structures and experimental conditions examined in this study, the equivalent uniform TCC model produces more stable and physically consistent results. Of the three factors that were the focus of the investigation, temperature was found to have the most significant impact, accounting for 59.27% of the total feature importance. It is evident that the TCC increases concomitantly with the rise of bolt torque; however, the growth rate gradually slows down. In the present study, the three combinations under investigation were found to exhibit varying levels of TCC. The aluminum alloy/aluminum alloy interface was found to exhibit the highest level of TCC, while the aluminum alloy/titanium alloy interface was found to exhibit the lowest. The mean error of the transient simulation employing the TCC obtained by steady-state inversion is approximately 3.40% and 1.04%, which demonstrates good reliability. This study elucidates the relationships between temperature, bolt torque, material combination, and the macroscopic equivalent TCC, providing a reference for thermal analysis and thermal design of relevant engineering structures.

Case Studies in Thermal EngineeringVol. 88
Hubei Urban Construction Vocational and Technological College (CN), Wuhan University of Science and Technology (CN)
Openalex Percentile: Top 19%
Heat Transfer and Numerical Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon