Equivalent circuit of a 6–10 kV cable network for locating single-phase earth faults using an artificial neural network

Location of single-phase earth faults in 6–10 kV cable networks is a challenging task, especially in the presence of complex transient processes and various neutral grounding regimes. Traditional methods based on the analysis of zero-sequence currents and voltages often require complex and time-consuming calculations and do not always provide high fault location accuracy. The use of artificial neural networks improves the efficiency of single-phase earth fault location through automatic transient analysis and adaptation to changing network conditions and parameters. However, training and testing the neural network requires an accurate equivalent circuit for the 6–10 kV cable network. To study transient processes during earth faults, T-shaped and L-shaped equivalent circuits of a 6–10 kV cable line have been used. Modeling of ground faults has been performed in MATLAB/Simulink. Also, an artificial neural network has been developed to determine the location of damage based on transient parameters. A T-shaped equivalent circuit for a 6–10 kV cable network is proposed, taking into account the portion of the network beyond the earth fault location. The trained neural network has demonstrated high fault location accuracy under various neutral grounding conditions and transient resistances. The use of a T-shaped equivalent circuit for a 6–10 kV cable network in training and testing an artificial neural network as the basis of the method of locating single-phase earth faults allows increasing its selectivity and adaptability. It is especially important for networks with a voltage of 6–10 kV operating with different neutral grounding modes for different types of earth faults.

Authors

Institutions

Publication Details

Journal
Vestnik IGEU
Published
2026-10-30
DOI
https://doi.org/10.17588/2072-2672.2026.5.062-071
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Equivalent circuit of a 6–10 kV cable network for locating single-phase earth faults using an artificial neural network

T.Yu. Shadrikova, I.A. Galanin
Vestnik IGEU
Power Systems Fault Detection
article

Equivalent circuit of a 6–10 kV cable network for locating single-phase earth faults using an artificial neural network

T.Yu. Shadrikova, I.A. Galanin
article en

Abstract

Location of single-phase earth faults in 6–10 kV cable networks is a challenging task, especially in the presence of complex transient processes and various neutral grounding regimes. Traditional methods based on the analysis of zero-sequence currents and voltages often require complex and time-consuming calculations and do not always provide high fault location accuracy. The use of artificial neural networks improves the efficiency of single-phase earth fault location through automatic transient analysis and adaptation to changing network conditions and parameters. However, training and testing the neural network requires an accurate equivalent circuit for the 6–10 kV cable network. To study transient processes during earth faults, T-shaped and L-shaped equivalent circuits of a 6–10 kV cable line have been used. Modeling of ground faults has been performed in MATLAB/Simulink. Also, an artificial neural network has been developed to determine the location of damage based on transient parameters. A T-shaped equivalent circuit for a 6–10 kV cable network is proposed, taking into account the portion of the network beyond the earth fault location. The trained neural network has demonstrated high fault location accuracy under various neutral grounding conditions and transient resistances. The use of a T-shaped equivalent circuit for a 6–10 kV cable network in training and testing an artificial neural network as the basis of the method of locating single-phase earth faults allows increasing its selectivity and adaptability. It is especially important for networks with a voltage of 6–10 kV operating with different neutral grounding modes for different types of earth faults.

Vestnik IGEU(5)
Ivanovo State Power University (RU)
Industry, innovation and infrastructure
Openalex Percentile: Top 18%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.