Centrifugal compressor surge in closed loop systems: modeling and comparison with experiments

Electrically driven heat pumps are expected to have a growing market for efficient and sustainable thermal supply in compliance with global decarbonization goals and renewable power penetration. Vapor compression heat pumps feature compact size, straightforward scaling-up, affordable costs, and good performance in terms of efficiency and low acoustic emissions. Large industrial applications usually implement dynamic compressors in particular, in either single or multi-stage configuration, requiring detailed on-design and off-design analysis, including reliable prediction of fluid dynamic instabilities such as surge & stall. This work presents a quasi-1D lumped-volume model focused on the post-stall (surge) dynamics of a radial compressor operating in a heat pump loop employing low-pressure refrigerant, validated through a dedicated experimental campaign, encompassing two different geometrical layouts of the test rig. The quasi 1-D model approach, represents an evolution of a preliminary 0-D simplified model, showing improved accuracy and retaining a physics-based formulation of the fundamental equations. Simulation and experimental results are compared in terms of surge frequency (0.6–1.2 Hz) and amplitude of compressor exit pressure fluctuations at different compressor speeds and with two test rig geometrical configurations, supporting its general validity. The expansion valve is not modeled and the heat exchanger liquid levels are held constant within the simulated surge cycles, consistently with the separation between the surge time scale (∼1 s) and the liquid level dynamics (tens of surge cycles). Finally, comparison with high-frequency experimental pressure data shows that the detailed model, despite its quasi 1-D representation of the physical rig, is also capable of predicting intermediate frequency (∼ 10 Hz) low-energy oscillations, consistent with the intermediate-frequency content found in the measured pressure spectra; their possible role as surge precursors remains to be verified experimentally.

Authors

Institutions

Publication Details

Journal
International Journal of Refrigeration
Published
2026-10-31
DOI
https://doi.org/10.1016/j.ijrefrig.2026.107199
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Centrifugal compressor surge in closed loop systems: modeling and comparison with experiments

Alberto Traverso, Sreenath Purushothaman, Marco Martins Afonso, Federico Reggio et al.
International Journal of Refrigeration
Refrigeration and Air Conditioning Technologies
article

Centrifugal compressor surge in closed loop systems: modeling and comparison with experiments

Alberto Traverso, Sreenath Purushothaman, Marco Martins Afonso, Federico Reggio, Chaitanya V. Halbe
article en

Abstract

Electrically driven heat pumps are expected to have a growing market for efficient and sustainable thermal supply in compliance with global decarbonization goals and renewable power penetration. Vapor compression heat pumps feature compact size, straightforward scaling-up, affordable costs, and good performance in terms of efficiency and low acoustic emissions. Large industrial applications usually implement dynamic compressors in particular, in either single or multi-stage configuration, requiring detailed on-design and off-design analysis, including reliable prediction of fluid dynamic instabilities such as surge & stall. This work presents a quasi-1D lumped-volume model focused on the post-stall (surge) dynamics of a radial compressor operating in a heat pump loop employing low-pressure refrigerant, validated through a dedicated experimental campaign, encompassing two different geometrical layouts of the test rig. The quasi 1-D model approach, represents an evolution of a preliminary 0-D simplified model, showing improved accuracy and retaining a physics-based formulation of the fundamental equations. Simulation and experimental results are compared in terms of surge frequency (0.6–1.2 Hz) and amplitude of compressor exit pressure fluctuations at different compressor speeds and with two test rig geometrical configurations, supporting its general validity. The expansion valve is not modeled and the heat exchanger liquid levels are held constant within the simulated surge cycles, consistently with the separation between the surge time scale (∼1 s) and the liquid level dynamics (tens of surge cycles). Finally, comparison with high-frequency experimental pressure data shows that the detailed model, despite its quasi 1-D representation of the physical rig, is also capable of predicting intermediate frequency (∼ 10 Hz) low-energy oscillations, consistent with the intermediate-frequency content found in the measured pressure spectra; their possible role as surge precursors remains to be verified experimentally.

International Journal of RefrigerationVol. 193
University of Genoa (IT)
Openalex Percentile: Top 23%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon